{"product_id":"range-setting-module-honeywell-fc-bsdol-04uni","title":"Range Setting Module Honeywell FC-BSDOL-04UNI","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-BSDOL-04UNI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager SC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, designed to provide high-accuracy range settings for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour loop-monitored output channels\u003c\/strong\u003e. It specifically supports the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSDOL-0424 digital output modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand mounts directly onto the programming connector ($Px$) of the I\/O backplane, enabling seamless integration and calibration of safety-critical output signals.\u003c\/p\u003e\n\u003cp\u003eEssential for applications requiring precise current sensing, the FC-BSDOL-04UNI helps prevent false \"lead breakage\" alarms and nuisance trips, ensuring reliable operation in safety-instrumented loops. Its modular architecture, consisting of a main section and 16 sub-modules, provides fine-grained control and maintenance flexibility in demanding industrial automation environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-BSDOL-04UNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRange setting for loop-monitored outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell SDOL-0424 modules \/ Safety Manager SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C (-4°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e120 mm × 60 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Operational Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Calibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-resolution adjustments ensure output current thresholds match field load conditions, improving loop diagnostic accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn redundant configurations, a single FC-BSDOL-04UNI supports a pair of SDOL-0424 modules, reducing cabinet space and hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Backplane Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects directly to the $Px$ programming connector, eliminating the need for external brackets or secondary wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSixteen sub-modules allow channel-by-channel tuning and simplified maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary purpose of the FC-BSDOL-04UNI?\u003c\/strong\u003e\u003cbr\u003eIt sets precise electrical \"ranges\" for loop-monitored digital outputs, ensuring the system can distinguish between normal operation and field faults, such as broken wires or shorts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require its own power source?\u003c\/strong\u003e\u003cbr\u003eNo, it draws 24 VDC through the Safety Manager I\/O backplane, simplifying installation and reducing wiring complexity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52495169061048,"sku":"FC-BSDOL-04UNI","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-BSDOL-04UNI.jpg?v=1769153720","url":"https:\/\/www.globalpetroparts.com\/products\/range-setting-module-honeywell-fc-bsdol-04uni","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}