{"product_id":"rockwell-prosoft-ilx69-pbs-profibus-slave-communication-module","title":"Rockwell Prosoft ILX69-PBS PROFIBUS Slave Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eProSoft ILX69-PBS\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS DP Slave Communication Module\u003c\/strong\u003e for the \u003cstrong\u003eRockwell Automation CompactLogix and MicroLogix\u003c\/strong\u003e platforms. It enables CompactLogix controllers to operate as \u003cstrong\u003ePROFIBUS DP slaves\u003c\/strong\u003e, allowing PROFIBUS DP masters (such as Siemens S7 PLCs or ProSoft master modules) to read and write data from the CompactLogix system. With support for \u003cstrong\u003eDP-V0 cyclic data\u003c\/strong\u003e and \u003cstrong\u003eDP-V1 acyclic messaging\u003c\/strong\u003e, this module provides robust interoperability in mixed-vendor automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e ILX69-PBS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS DP Slave Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ProSoft ILX69 for CompactLogix\/MicroLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatform:\u003c\/strong\u003e Rockwell CompactLogix, MicroLogix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e PROFIBUS DP-V0 \/ DP-V1 Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Connector:\u003c\/strong\u003e 9-pin D-Sub female\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × RJ45 (10\/100 Mbps) for configuration\/diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cyclic Input Data:\u003c\/strong\u003e 244 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cyclic Output Data:\u003c\/strong\u003e 244 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcyclic Data:\u003c\/strong\u003e DPV1 Class 1 read\/write supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Setting:\u003c\/strong\u003e Rotary switches (0–99) or software configuration (0–125)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e ProSoft Configuration Builder (PCB); Studio 5000 AOI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e +5VDC via backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 131.6 × 92.1 × 39.3 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 152 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL\/cUL Class 1 Div 2, CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative CompactLogix Integration:\u003c\/strong\u003e Plugs directly into 1769 CompactLogix backplane as standard I\/O module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP-V1 Support:\u003c\/strong\u003e Enables acyclic parameter access and extended diagnostics from PROFIBUS masters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Diagnostics:\u003c\/strong\u003e Dedicated RJ45 port for web-based diagnostics and remote firmware updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Addressing:\u003c\/strong\u003e Rotary switches for quick address assignment or software configuration for addresses above 99\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSD Card Slot:\u003c\/strong\u003e Removable memory card stores configuration for rapid field replacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Small footprint ideal for space-constrained control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompactLogix systems integrated into Siemens-dominated PROFIBUS networks\u003c\/li\u003e\n\u003cli\u003eAutomotive plants with mixed Rockwell\/Siemens control architectures\u003c\/li\u003e\n\u003cli\u003ePackaging OEM machines requiring PROFIBUS slave interface for customer integration\u003c\/li\u003e\n\u003cli\u003eProcess skids with CompactLogix controllers interfacing to DCS PROFIBUS masters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e De-energize the CompactLogix rack before module installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Insert the ILX69-PBS into any available 1769 slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIBUS Connection:\u003c\/strong\u003e Connect the 9-pin D-Sub to the PROFIBUS network bus cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Setting:\u003c\/strong\u003e Set the rotary switches to the desired PROFIBUS station address (1–99)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Setup:\u003c\/strong\u003e Connect the RJ45 port to your laptop for initial configuration via web interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudio 5000:\u003c\/strong\u003e Add the module using the ProSoft AOP or generic 1769 module profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Configuration:\u003c\/strong\u003e Define input\/output data lengths, DPV1 parameters, and module behavior\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSD File:\u003c\/strong\u003e Provide the ProSoft GSD file to your PROFIBUS master system engineer for network integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up and verify cyclic data exchange via master diagnostic tools\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ILX69-PBS operate as a PROFIBUS master?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo\u003c\/strong\u003e, this module is a \u003cstrong\u003ePROFIBUS DP slave only\u003c\/strong\u003e. For master functionality on CompactLogix, use \u003cstrong\u003eILX69-PBM\u003c\/strong\u003e or \u003cstrong\u003eMVI69-PDPMV1\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I set an address above 99?\u003c\/strong\u003e\u003cbr\u003e\nA: Set both rotary switches to \u003cstrong\u003e0\u003c\/strong\u003e and configure the address via the \u003cstrong\u003ePCB software or Studio 5000 tag\u003c\/strong\u003e (supports 0–125).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the Ethernet port required for operation?\u003c\/strong\u003e\u003cbr\u003e\nA: No, the Ethernet port is for \u003cstrong\u003econfiguration and diagnostics only\u003c\/strong\u003e. PROFIBUS communication operates independently via the DB9 connector.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this with Micro800 controllers?\u003c\/strong\u003e\u003cbr\u003e\nA: The ILX69-PBS is designed for \u003cstrong\u003eCompactLogix and MicroLogix\u003c\/strong\u003e. For Micro800, consult ProSoft for compatible gateway solutions.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your PROFIBUS master system engineer has the correct GSD file before commissioning\u003c\/li\u003e\n\u003cli\u003eFor redundant PROFIBUS networks, plan for dual-cable infrastructure at the master level\u003c\/li\u003e\n\u003cli\u003eUse the SD card to back up configurations — store spares with pre-loaded configs for rapid replacement\u003c\/li\u003e\n\u003cli\u003eEnsure proper PROFIBUS termination at both ends of the bus segment\u003c\/li\u003e\n\u003cli\u003eConsider ILX69-PBS-XT for installations in hazardous or extreme temperature environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":53776587194552,"sku":"MVI56-101MILX69-PBS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/MVI56-PDPMV1_r180.png?v=1784182887","url":"https:\/\/www.globalpetroparts.com\/products\/rockwell-prosoft-ilx69-pbs-profibus-slave-communication-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}