{"product_id":"schneider-electric-tsxpsy2600m-ac-power-supply-module","title":"Schneider Electric TSXPSY2600M AC Power Supply Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSY2600M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-efficiency AC power supply module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric Modicon Premium (TSX 57) PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It converts universal AC input into stable DC voltages required by the processor and I\/O modules via the backplane. Engineered for resilience against utility power fluctuations, this module ensures reliable operation of mid-sized Premium PLC racks while providing dedicated 24V power for sensors and actuators.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100V to 240V AC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85V to 264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Useful Secondary Power\u003c\/td\u003e\n\u003ctd\u003e26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e5V DC (Internal Bus), 24V DC (Sensors\/Actuators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Current\u003c\/td\u003e\n\u003ctd\u003e3.6 A at 5V DC \/ 0.6 A at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e300 mA at 240V \/ 500 mA at 100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e37 A at 100V \/ 75 A at 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 MΩ at 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInternal fuse, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10%–95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Context\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated warehousing and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood and beverage processing lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSXPSY2600M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emid-sized Premium racks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombining digital and analog I\/O modules, providing both stable bus power and a dedicated 24V output for field devices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the power LED is not illuminated?\u003c\/strong\u003e\u003cbr\u003eVerify that the input voltage is within 85–264V AC. If the LED remains off, the internal fuse may have tripped due to a short circuit or module fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module power 24V field sensors?\u003c\/strong\u003e\u003cbr\u003eYes. The module provides a 24V DC output for sensors and small actuators, with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaximum total current of 0.6 A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52526062764216,"sku":"TSXPSY2600M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TSXPSY2600M2_2.jpg?v=1770102377","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-electric-tsxpsy2600m-ac-power-supply-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}