{"product_id":"schneider-modicon-quantum-140cra93100-rio-drop-adaptor-module","title":"Schneider Modicon Quantum 140CRA93100 RIO drop adaptor module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric 140CRA93100 acts as the primary interface between a Remote I\/O (RIO) drop and the Modicon Quantum network. This module manages the communication between the local I\/O backplane and the remote head processor. It ensures synchronized, deterministic data exchange across the industrial site. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your system architecture maintains peak signal integrity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 140CRA93100 utilizes a high-speed coaxial interface to facilitate long-distance communication without sacrificing data throughput.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Medium\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial Cable (RG-6 or RG-11)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.544 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Current Required\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAddress Settings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo Rotary Switches (1 to 63)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Vdc for 1 minute between RIO and ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED Indicators for Active, Ready, and Communication Error\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterruption Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 1 ms (Power Loss)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Network Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 140CRA93100 allows engineers to distribute I\/O modules across vast distances—up to 15,000 feet with repeaters—reducing the need for massive central wiring runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Address Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo physical rotary switches on the front panel provide immediate visual confirmation of the drop address. This hardware-based approach speeds up commissioning and simplifies troubleshooting during site audits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s coaxial interface inherently rejects electromagnetic interference (EMI) and radio frequency interference (RFI), making it ideal for environments with heavy motor drives or high-voltage switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-mounted status LEDs provide real-time feedback. The \"Com Error\" indicator instantly flags physical layer issues, such as loose BNC connectors or cable breaks, minimizing downtime during critical failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 140CRA93100 require specific software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware address is set via rotary switches. However, you must configure the RIO drop in your PLC software (Unity Pro, Concept, or EcoStruxure Control Expert) to match the physical switch settings and define the I\/O map.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with fiber optic cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 140CRA93100 features a BNC connector for coaxial cable. To integrate this module into a fiber optic backbone, you must use a 140CRP series head processor or an external fiber optic repeater\/converter (such as the 490NRP series).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 600 mA current draw?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis value represents the power the module pulls from the Quantum backplane. When designing your RIO drop, ensure the power supply module (e.g., 140CPS series) provides sufficient amperage to support the 140CRA93100 plus all installed I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a direct replacement for legacy Modicon 800 Series RIO adapters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it performs the same function within the Quantum family, it is specifically designed for the Quantum backplane. If you are migrating from an 800 Series system, the 140CRA93100 allows you to bring that remote site into a modern Quantum or M580 architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53379811639480,"sku":"140CRA93100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140CRA93100_3_1.jpg?v=1776836718","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-modicon-quantum-140cra93100-rio-drop-adaptor-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}