{"product_id":"schneider-modicon-quantum-140ddo15310-discrete-output-module-1","title":"Schneider Modicon Quantum 140DDO15310 Discrete Output Module","description":"\u003ch3\u003eSchneider Electric 140DDO15310 Modicon Quantum Discrete Output Module — 32-Point, 5VDC TTL, Sink Type\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e140DDO15310\u003c\/strong\u003e is a \u003cstrong\u003e32-point discrete output module\u003c\/strong\u003e for Schneider Electric's \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e automation platform. It provides \u003cstrong\u003eTTL-level transistor outputs (sink type \/ negative logic)\u003c\/strong\u003e with high-speed switching capability, making it ideal for interfacing with TTL-compatible devices, solenoids, relays, and indicators in industrial control systems. The module features \u003cstrong\u003e4 groups of 8 channels\u003c\/strong\u003e, integrated LED diagnostics, and built-in surge protection for reliable operation.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Quantum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Discrete Output Module (TTL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 32 (4 groups of 8)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Logic:\u003c\/strong\u003e Sink type (negative logic)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 5 VDC (4–5.5 VDC range)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Positive (heat sink) TTL level\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Load Current:\u003c\/strong\u003e ≤ 75 mA per point; ≤ 600 mA per group; ≤ 2.4 A per module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 750 A for 0.5 ms per point\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤ 250 µs (1→0 and 0→1, resistive load)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAbsolute Max Output:\u003c\/strong\u003e 15 V for 0.0013 s decay voltage pulse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 4 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Current Required:\u003c\/strong\u003e 350 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Internal fuse protection; transient voltage suppression (TVS) on outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e 32 × green LEDs (output status 1–32); 1 × red LED (external fault F); 1 × green LED (bus communication active)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e SUB-D 50-pin female (CableFast compatible)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Quantum backplane slot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 27 × 10 × 4.5 cm (L × W × H)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg (0.99 lb)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddress Requirement:\u003c\/strong\u003e 2 output words\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e France\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61131-3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Active \/ In production\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eArchitecture \u0026amp; Functionality\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrouped Outputs:\u003c\/strong\u003e 4 groups of 8 channels for flexible wiring and isolation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCableFast Compatibility:\u003c\/strong\u003e Supports CableFast terminal blocks for quick field wiring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Switching:\u003c\/strong\u003e ≤ 250 µs response time for fast control applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e 750 A peak surge current handling per point\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Red LED indicates blown fuse or external fault condition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Communication:\u003c\/strong\u003e Green LED confirms active backplane communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eInstall the 140DDO15310 into a \u003cstrong\u003estandard I\/O slot\u003c\/strong\u003e on the Quantum backplane.\u003c\/li\u003e\n  \u003cli\u003eConnect the \u003cstrong\u003eSUB-D 50-pin female connector\u003c\/strong\u003e to field devices using CableFast wiring system or custom cabling.\u003c\/li\u003e\n  \u003cli\u003eEnsure \u003cstrong\u003eload current\u003c\/strong\u003e does not exceed 75 mA per point, 600 mA per group, or 2.4 A per module.\u003c\/li\u003e\n  \u003cli\u003eVerify \u003cstrong\u003eoutput voltage\u003c\/strong\u003e is 5 VDC TTL compatible with downstream devices.\u003c\/li\u003e\n  \u003cli\u003ePower on and verify all \u003cstrong\u003e32 green LEDs\u003c\/strong\u003e illuminate for active outputs; check red LED for fault indication.\u003c\/li\u003e\n  \u003cli\u003eConfigure output addressing in \u003cstrong\u003eUnity Pro\u003c\/strong\u003e or \u003cstrong\u003eConcept\u003c\/strong\u003e programming software (requires 2 output words).\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is 140DDO15310 source or sink type?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eSink type (negative logic).\u003c\/strong\u003e The module sinks current from the load to ground. For source type (positive logic), use 140DDO35301.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 140DDO15310 and 140DDO35310?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003e140DDO15310\u003c\/strong\u003e is \u003cstrong\u003e5 VDC TTL\u003c\/strong\u003e output. \u003cstrong\u003e140DDO35310\u003c\/strong\u003e is \u003cstrong\u003e24 VDC negative logic (sink)\u003c\/strong\u003e output. Both are 32-point modules but with different voltage ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 140DDO15310 and 140DDO35300?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003e140DDO35300\u003c\/strong\u003e is a \u003cstrong\u003e32-point solid-state output module\u003c\/strong\u003e with different voltage\/current specifications. 140DDO15310 is specifically designed for \u003cstrong\u003e5 VDC TTL\u003c\/strong\u003e applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use 140DDO15310 with 24 VDC loads?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e This module outputs \u003cstrong\u003e5 VDC TTL\u003c\/strong\u003e only. For 24 VDC loads, use 140DDO35310 (sink) or 140DDO35301 (source).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is CableFast compatibility?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eCableFast\u003c\/strong\u003e is Schneider Electric's quick-connect terminal block system that plugs directly into the SUB-D connector, eliminating individual wire termination and reducing installation time.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is 140DDO15310 compatible with M580?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e 140DDO15310 is designed for \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e racks. M580 uses different I\/O module architecture (e.g., BMXDDO series).\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantum, 32-point, 5VDC TTL, sink:\u003c\/strong\u003e 140DDO15310\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantum, 32-point, 24VDC, sink:\u003c\/strong\u003e 140DDO35310\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantum, 32-point, 24VDC, source:\u003c\/strong\u003e 140DDO35301\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantum, 32-point, solid-state:\u003c\/strong\u003e 140DDO35300\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Load voltage (5V TTL vs 24VDC), logic type (source vs sink), and current requirements before ordering\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder compatible connector:\u003c\/strong\u003e CableFast terminal block or SUB-D 50-pin cable assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy from Us?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100% Genuine Schneider Electric product\u003c\/li\u003e\n  \u003cli\u003eBrand new, factory-sealed\u003c\/li\u003e\n  \u003cli\u003e12-month warranty\u003c\/li\u003e\n  \u003cli\u003eFast global shipping (FedEx, UPS, DHL)\u003c\/li\u003e\n  \u003cli\u003eTechnical support for Unity Pro \/ Concept\u003c\/li\u003e\n  \u003cli\u003eBulk pricing for OEM and system integrators\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003eReference: Schneider Electric 140DDO15310 Product Data Sheet; MRO Electric specifications; Automation Mall technical parameters; Cambia PLC product documentation. Specifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53731076571320,"sku":"140DDO15310","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140DDO15310.png?v=1783584541","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-modicon-quantum-140ddo15310-discrete-output-module-1","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}