{"product_id":"schneider-modicon-quantum-140dra84000-16-channel-relay-discrete-output-module","title":"Schneider Modicon Quantum 140DRA84000 16-Channel Relay Discrete Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric 140DRA84000 provides versatile power switching capabilities for the Modicon Quantum automation platform. This module features 16 independent Normally Open (1 NO) Form A relay contacts, allowing the PLC to control a wide range of AC and DC field devices. It bridges the gap between low-level logic and high-power actuators like motor starters, interposing relays, and solenoid valves. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring optimal contact surface integrity and mechanical reliability for your high-availability control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 140DRA84000 manages diverse voltage ranges and load types with high electrical durability.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay (Form A - 1 NO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20...250 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5...30 V DC \/ 30...150 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A at 250V AC \/ 30V DC (Resistive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e 10 ms (Off to On) \/ \u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e 20 ms (On to Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A for 10 ms (Capacitive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Varistor (275 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation (Channel to Bus)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1780 Vrms AC \/ 2500 V DC for 1 min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Current Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1100 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Voltage Switching Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne 140DRA84000 module simultaneously controls AC and DC loads across a massive voltage spectrum (\u003cspan class=\"math-inline\"\u003e$5$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV DC to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$250$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV AC). This flexibility eliminates the need for separate DC and AC output cards in hybrid control environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Isolation Barriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1780$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eVrms isolation between individual channels and between the channels and the backplane bus. This prevents field-side electrical noise and transient surges from migrating into the sensitive PLC processor electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Surge Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$275$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV varistors protect the internal relay contacts from inductive kickback and overvoltage spikes. This internal protection significantly extends the electrical life of the module and reduces the need for external snubbers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach relay supports up to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$2$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eA resistive loads at\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$60$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e°C. This allows the module to drive many medium-sized industrial actuators directly, reducing the cost and cabinet space required for external interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Visual Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 dedicated green LEDs provide immediate status for each output point. A separate red \"Fault\" LED and a green \"Active\" LED allow maintenance teams to verify bus communication and identify external fault conditions at a glance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 140DRA84000 require an external power supply for the relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1100$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emA from the Quantum backplane to energize the relay coils. However, you must provide the external power source (\u003cspan class=\"math-inline\"\u003e$20-250$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV AC or\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$5-150$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV DC) for the loads you intend to switch through the contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the 140DRA84000 features isolated relay contacts, you can wire different voltage sources to different channels. Ensure you maintain proper wiring separation and adhere to the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$1780$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eVrms isolation limits between channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between \"Mechanical\" and \"Electrical\" durability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMechanical durability (\u003cspan class=\"math-inline\"\u003e$10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emillion cycles) represents the life of the relay without a load. Electrical durability (\u003cspan class=\"math-inline\"\u003e$100,000$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$200,000$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ecycles) indicates the expected life when switching rated current. Switching high-inductive loads without external suppression will reduce electrical durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal block should I use for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires the standard Modicon Quantum 40-pin screw terminal block, model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140XTS00200\u003c\/strong\u003e. We recommend using the correct wire gauge (up to 14 AWG) to handle the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$2$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eA maximum load per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53380052123832,"sku":"140DRA84000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140DRA84000_2_d38a229e-25f8-43e8-a34e-50b2e44c2ed3.jpg?v=1776843991","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-modicon-quantum-140dra84000-16-channel-relay-discrete-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}