{"product_id":"schneider-modicon-quantum-170aao92100-analogue-output-base","title":"Schneider Modicon Quantum 170AAO92100 Analogue Output Base","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric 170AAO92100 functions as a high-precision analogue output base within the Modicon Momentum distributed I\/O family. This module provides four independent channels to drive field actuators, valves, and variable speed drives. It processes data in a full 16-bit signed format, ensuring granular control for sensitive process loops. By supporting both voltage (\u003cspan class=\"math-inline\"\u003e$\\pm10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV) and current (\u003cspan class=\"math-inline\"\u003e$4...20$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emA) signals, this base offers the versatility required for diverse industrial architectures. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, guaranteeing factory-calibrated accuracy for your automation infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 170AAO92100 delivers rapid updates and robust isolation for stable signal transmission in noisy environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull 16 bits signed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm10$\u003c\/span\u003e V (\u003cspan class=\"math-inline\"\u003e$\\ge$\u003c\/span\u003e 1 kOhm) \/ \u003cspan class=\"math-inline\"\u003e$4...20$\u003c\/span\u003e mA (\u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e 0.6 kOhm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAbsolute Accuracy Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm0.2\\%$\u003c\/span\u003e of full scale (\u003cspan class=\"math-inline\"\u003e$\\pm10$\u003c\/span\u003e V @ 25°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V AC for 1 minute (Channels to Ground)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Permissible limits \u003cspan class=\"math-inline\"\u003e$\\pm30$\u003c\/span\u003e V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated (Voltage circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Green LEDs (Channel Status)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.47 lb (0.215 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit signed data format provides superior resolution compared to standard 12-bit modules. This enables precise positioning of control valves and smoother ramp speeds for high-power motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Process Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 2 ms update time ensures the module synchronizes effectively with high-speed PLC scan cycles. This minimizes lag in critical PID control loops, preventing process oscillations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Fail-Safe States:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module allows engineers to define the output behavior during a communication loss. You can program the channels to \"Hold\" the last value, \"Reset to Zero,\" or \"Reset to Full Scale,\" preventing catastrophic equipment movement during network failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Power Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 170AAO92100 operates on a wide 24 V DC range (up to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm30$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV DC). This tolerance accommodates unstable power conditions often found in remote distributed I\/O stations or solar-powered utility sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Protection Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal 2 A slow-blow fuses and reverse polarity protection safeguard the base against wiring errors. The built-in short-circuit protection for voltage outputs prevents hardware failure if field cables suffer mechanical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix voltage and current outputs on the same 170AAO92100 base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports both ranges, but you must configure the outputs according to the hardware terminal wiring and software parameters. It serves as a universal base for both signal types across its 4 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the outputs if the 24V DC external power fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires external 24V DC to drive the actuators. If this power is lost, the outputs will drop to zero regardless of the programmed \"Fail State\" settings, as the output circuitry loses its driving force.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate communication adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 170AAO92100 is an I\/O base. To function within a network, you must snap on a Momentum communication adapter (such as a 170PNT series for Profibus or 170ENT for Ethernet) or a Momentum processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 170AAO92100 compatible with high-altitude installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is rated for operation up to 5,000 meters (16,404 ft), making it ideal for high-altitude mining operations and aerospace test facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53379956801720,"sku":"170AAO92100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/170AAO92100_3.jpg?v=1776839297","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-modicon-quantum-170aao92100-analogue-output-base","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}