{"product_id":"schneider-modicon-quantum-6-channel-isolated-ac-discrete-output-module-140dao84000","title":"Schneider Modicon Quantum 6-Channel Isolated AC Discrete Output Module 140DAO84000","description":"\u003ch3 data-path-to-node=\"7\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003eThe Schneider Electric 140DAO84000 provides high-performance discrete switching for AC-powered field devices within the Modicon Quantum ecosystem. This module features 16 independent, fully isolated output channels, allowing engineers to switch loads across different AC phases or voltage sources without risk of cross-channel interference. It manages a broad voltage spectrum from 20V to 253V AC, making it a universal choice for controlling solenoids, motor starters, and actuators. We supply this module as \u003cb data-path-to-node=\"8\" data-index-in-node=\"510\"\u003e100% Brand New and Original\u003c\/b\u003e, ensuring peak isolation barriers and long-term switching endurance for critical industrial processes.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe 140DAO84000 utilizes robust Triac-based switching to handle high surge currents and frequent cycle operations.\u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eTrue Per-Channel Isolation:\u003c\/b\u003e Unlike standard grouped-channel modules, the 140DAO84000 isolates each of its 16 channels. This architecture permits the control of multiple independent power circuits from a single module, effectively reducing the need for interposing isolation relays and extra hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eExceptional Surge Handling:\u003c\/b\u003e The module withstands massive inrush currents—up to 30A for one cycle. This capability proves critical when driving inductive loads like large solenoid valves or AC contactors that draw high initial current upon activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eUltra-Fast Switching Logic:\u003c\/b\u003e A response time of \u003cspan class=\"math-inline\" data-math=\"\\le\" data-index-in-node=\"47\"\u003e$\\le$\u003c\/span\u003e 0.5 ms ensures the module tracks the PLC logic with zero noticeable lag. This precision facilitates tight control in high-speed sorting and safety interlocking applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eEnhanced Transient Immunity:\u003c\/b\u003e Integrated RC filters provide internal protection against high \u003cspan class=\"math-inline\" data-math=\"dV\/dt\" data-index-in-node=\"92\"\u003e$dV\/dt$\u003c\/span\u003e (400 V\/ms) transients. This prevents the Triacs from accidental triggering caused by electrical noise on the AC grid, ensuring the output only fires when the CPU commands it.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-path-to-node=\"13,4,0\" data-index-in-node=\"0\"\u003eGlobal Environmental Compliance:\u003c\/b\u003e Rated for altitudes up to 5,000 meters and certified for FM Class 1 Division 2, this module operates reliably in explosive atmospheres, high-elevation mining sites, and standard manufacturing floors alike.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eFAQs\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eDoes the 140DAO84000 require an external fuse?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eYes. Schneider Electric recommends using an associated 5A fuse per channel to protect the internal Triacs from short-circuit conditions in the field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eCan I use this module to switch DC loads?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eNo. This module utilizes AC-specific switching components (Triacs) that require a zero-crossing to turn off. Attempting to switch DC will result in the output \"latching\" on until physical power is removed. Use a 140DDO series module for DC applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eHow does the 140DAO84000 handle leakage current with small loads?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003eThe module has a specified off-state leakage current (e.g., 2.5 mA at 230V). If you are driving extremely high-impedance loads like small neon indicators or sensitive relay coils, this leakage might keep the load energized. In such cases, install a bleeder resistor in parallel with the load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eIs the terminal block included with the module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003eAs a brand-new unit, it comes as the module only. You must purchase the 40-pin screw terminal block (140XTS00200) separately to complete the field wiring termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53380035117240,"sku":"140DAO84000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140DRA84000_1.jpg?v=1776843217","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-modicon-quantum-6-channel-isolated-ac-discrete-output-module-140dao84000","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}