{"product_id":"schneider-modicon-quantum-bmxsdo0802-x80-discrete-output-module","title":"Schneider Modicon Quantum BMXSDO0802 X80 Discrete Output Module","description":"\u003ch3\u003eSchneider Electric BMXSDO0802 Modicon X80 Safety Discrete Output Module — 8-Channel, 24VDC, SIL3\/Cat4\/PLe\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBMXSDO0802\u003c\/strong\u003e is a \u003cstrong\u003esafety discrete output module\u003c\/strong\u003e for Schneider Electric's \u003cstrong\u003eModicon X80\u003c\/strong\u003e I\/O platform, compatible with \u003cstrong\u003eM580 Safety\u003c\/strong\u003e and \u003cstrong\u003eQuantum\u003c\/strong\u003e PAC systems. It provides \u003cstrong\u003e8 non-isolated solid-state outputs\u003c\/strong\u003e at \u003cstrong\u003e24 VDC positive logic\u003c\/strong\u003e, achieving \u003cstrong\u003eSIL3, Category 4, Performance Level e (PLe)\u003c\/strong\u003e compliance for critical safety applications. The module features \u003cstrong\u003eexternal pre-actuator power supply monitoring\u003c\/strong\u003e, comprehensive LED diagnostics, and conformal coating for harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon X80 (M580 Safety \/ Quantum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Safety Discrete Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 non-isolated outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Solid-state (transistor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Logic:\u003c\/strong\u003e Positive (source)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC nominal (18–30 VDC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.5 A per channel; 4 A max per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e ≤ 48 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Tungsten Load:\u003c\/strong\u003e 6 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e 0.5\/LP Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 1.2 ms (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e 16 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e \u0026lt; 14 VDC (sensor fault); \u0026gt; 18 VDC (sensor OK)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParalleling of Outputs:\u003c\/strong\u003e Yes, max 2 outputs in parallel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eReverse polarity protection (reverse mounted diode)\u003c\/li\u003e\n\u003cli\u003eOverload protection (current limiter + electronic circuit breaker, 1.5–2×In)\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection (internal diode)\u003c\/li\u003e\n\u003cli\u003eShort-circuit protection (with 2 A external fast-blow fuse)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 4.4 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical Current Consumption:\u003c\/strong\u003e 264 mA at 3.3 VDC; 16 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF Reliability:\u003c\/strong\u003e 401,208 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +60°C (-13°F to +140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5–95% at 55°C without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e 0–2000 m (2000–5000 m with derating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Gas class 3C4, Dust class 3S4, Salt level 2, Mold class 3B2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 1500 VAC 50\/60 Hz for 1 min (output\/ground and output\/internal logic)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 3 gn\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 15 gn\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Treatment:\u003c\/strong\u003e Conformal coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Format:\u003c\/strong\u003e Standard, 1 slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.12 kg (0.26 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Weight:\u003c\/strong\u003e 1.96 kg (4.33 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Dimensions:\u003c\/strong\u003e 5.5 × 17.5 × 26 cm (H × W × L)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Active \/ In production\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLED Indicators \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN LED (green):\u003c\/strong\u003e Module in operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eERR LED (red):\u003c\/strong\u003e Detected module error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O LED (red):\u003c\/strong\u003e Detected I\/O error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLCK LED (bi-color green\/red):\u003c\/strong\u003e Configuration status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 LED per channel (bi-color green\/red):\u003c\/strong\u003e Individual channel status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTerminal Block \u0026amp; Wiring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e 20-way removable terminal block (ordered separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Terminal Blocks:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMXFTB2010:\u003c\/strong\u003e Screw clamp terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMXFTB2000:\u003c\/strong\u003e Cage clamp terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMXFTB2020:\u003c\/strong\u003e Spring type terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Power Supply:\u003c\/strong\u003e 24 VDC PELV (Protected Extra Low Voltage), overvoltage category II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Fuse:\u003c\/strong\u003e Fast-blow fuse, max 6 A, required to protect external power supply against short-circuit and overvoltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin Assignment:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOutputs 0–7: Pins 2, 4, 6, 8, 10, 12, 14, 16\u003c\/li\u003e\n\u003cli\u003eCommon 0V: Pins 1, 3, 5, 7, 9, 11, 13, 15, 17, 19 (internally connected)\u003c\/li\u003e\n\u003cli\u003e24 VDC Process Power: Pins 18, 20 (internally connected)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL3\u003c\/strong\u003e (Safety Integrity Level 3) per IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory 4 (Cat4)\u003c\/strong\u003e per ISO 13849-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance Level e (PLe)\u003c\/strong\u003e per ISO 13849-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e SELV or PELV acceptable (both are Extra-Low-Voltage systems ≤ 50 VAC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the BMXSDO0802 into a \u003cstrong\u003estandard X80 backplane slot\u003c\/strong\u003e (M580 Safety or Quantum rack).\u003c\/li\u003e\n\u003cli\u003eSecure the module with the \u003cstrong\u003ecaptive screw\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInstall the \u003cstrong\u003e20-way removable terminal block\u003c\/strong\u003e (BMXFTB2010\/2000\/2020) into the front connector.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003e24 VDC PELV process power supply\u003c\/strong\u003e to pins 18 and 20.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003efield actuators\u003c\/strong\u003e (solenoids, contactors, motor starters) to output pins 2, 4, 6, 8, 10, 12, 14, 16.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003ecommon 0V\u003c\/strong\u003e to pins 1, 3, 5, 7, 9, 11, 13, 15, 17, 19.\u003c\/li\u003e\n\u003cli\u003eInstall a \u003cstrong\u003efast-blow external fuse (max 6 A)\u003c\/strong\u003e in the process power supply line.\u003c\/li\u003e\n\u003cli\u003eConfigure \u003cstrong\u003efallback mode and fallback timeout\u003c\/strong\u003e via Control Expert Safety software.\u003c\/li\u003e\n\u003cli\u003ePower on and verify \u003cstrong\u003eRUN LED\u003c\/strong\u003e (green) and channel status LEDs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What safety integrity level does BMXSDO0802 achieve?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eSIL3, Category 4, Performance Level e (PLe)\u003c\/strong\u003e per IEC 61508 and ISO 13849-1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use SELV or PELV power supply?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eBoth are acceptable.\u003c\/strong\u003e Both SELV and PELV are Extra-Low-Voltage systems (≤ 50 VAC). SELV has higher requirements than PELV and can be used instead of PELV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between BMXSDO0802 and BMXDDO1602?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eBMXSDO0802\u003c\/strong\u003e is a \u003cstrong\u003esafety\u003c\/strong\u003e output module (8 channels, SIL3\/Cat4\/PLe). \u003cstrong\u003eBMXDDO1602\u003c\/strong\u003e is a \u003cstrong\u003estandard\u003c\/strong\u003e discrete output module (16 channels, non-safety).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does BMXSDO0802 require an external fuse?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eYes.\u003c\/strong\u003e A \u003cstrong\u003efast-blow fuse (max 6 A)\u003c\/strong\u003e is required to protect the external power supply against short-circuit and overvoltage conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens when a safety fault is detected?\u003c\/strong\u003e\u003cbr\u003eA: The module sets its outputs to the \u003cstrong\u003esafe state (de-energized)\u003c\/strong\u003e and maintains this state until the fault is cleared and the module is restarted. Fallback state (energized, de-energized, or hold last value) is configurable via Control Expert Safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is BMXSDO0802 compatible with M340?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e BMXSDO0802 is designed for \u003cstrong\u003eM580 Safety\u003c\/strong\u003e and \u003cstrong\u003eQuantum\u003c\/strong\u003e systems. M340 does not support safety I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580 Safety, 8-channel safety output, SIL3\/Cat4\/PLe:\u003c\/strong\u003e BMXSDO0802\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580 Safety, 16-channel safety input:\u003c\/strong\u003e BMXSDI1602\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580 Safety, 4-channel safety relay output:\u003c\/strong\u003e BMXSRA0405\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard X80, 16-channel discrete output:\u003c\/strong\u003e BMXDDO1602\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Safety integrity level requirement, process power supply type (PELV\/SELV), and external fuse rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder compatible terminal block:\u003c\/strong\u003e BMXFTB2010 (screw), BMXFTB2000 (cage), or BMXFTB2020 (spring)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53758831100088,"sku":"BMXSDO0802","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/BMXSDO0802.png?v=1783584539","url":"https:\/\/www.globalpetroparts.com\/products\/schneider-modicon-quantum-bmxsdo0802-x80-discrete-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}