{"product_id":"series-90-70-ge-fanuc-ic697pwr711-100-watt-ac-dc-power-supply-module","title":"Series 90-70 | GE Fanuc IC697PWR711 | 100-Watt AC\/DC Power Supply Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC697PWR711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary power engine for the Series 90-70 PLC rack. This high-capacity 100-Watt module converts standard AC or DC input voltages into the stabilized triple-output DC voltages (+5V, +12V, and -12V) required to drive the CPU and I\/O modules across the backplane. It features a wide input range and exceptional voltage regulation to maintain system logic integrity during power fluctuations. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock, ensuring your legacy high-performance systems receive maximum lifespan and electrical stability.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90-132 VAC or 180-264 VAC (Auto-ranging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 150 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Watts Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5.07V Nominal, +12V, -12V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e+5V Current Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Amps (Typical), 26 Amps (Limit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHoldup Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 Milliseconds (Minimum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 0.93\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeak Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 Amps Typical \/ 77 Amps Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60°C (32 to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.63 lbs (1.64 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Holdup Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC697PWR711 provides a minimum holdup time of 21 milliseconds. This allows the PLC to ride through momentary power dips or switch-over transients without triggering a CPU reset, keeping your process running during minor grid instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Input Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accepts both universal AC (120\/240V) and 125V DC inputs. This dual-source compatibility enables engineers to standardize on a single power supply part number across facilities with different local utilities or battery-backed DC bus systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Voltage Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSophisticated internal circuitry maintains the +5V logic rail within a tight window (4.90 to 5.25V). This precision prevents bit errors and communication faults in high-density Series 90-70 racks packed with sensitive analog or communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Protections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe power supply incorporates active overvoltage and overcurrent limits. If a field-side short circuit occurs, the IC697PWR711 clamps the output to protect the expensive CPU and I\/O cards from permanent thermal damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the module for 120VAC vs. 240VAC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC697PWR711 features auto-ranging capabilities for AC input. The module automatically detects the incoming voltage level and adjusts its internal conversion stages without requiring manual jumper settings or switch changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the -12V output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the +5V rail powers the main logic, certain specialized analog modules and high-speed communication cards within the Series 90-70 line require the +\/- 12V rails for operational amplifiers and signal conditioning. This module provides all three rails to ensure full compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support redundant power configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard Series 90-70 baseplates host a single power supply. For high-availability applications requiring redundancy, you must utilize specific redundant baseplates and cables designed to bridge two power supply modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or \"New-Old-Stock\" unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe offer this IC697PWR711 as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. This is critical for power supplies, as internal electrolytic capacitors degrade over time in used units. Our brand-new stock ensures the capacitors and power transistors provide the full 100W rated capacity from day one.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53081945211064,"sku":"IC697PWR711","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC697PWR710_740b79b2-5770-4d28-9f38-986994cdc7cd.jpg?v=1774257639","url":"https:\/\/www.globalpetroparts.com\/products\/series-90-70-ge-fanuc-ic697pwr711-100-watt-ac-dc-power-supply-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}