{"product_id":"siemens-6es7193-6bp00-0da0-simatic-et-200sp-base-unit","title":"Siemens 6ES7193-6BP00-0DA0 SIMATIC ET 200SP Base Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6ES7193-6BP00-0DA0\u003c\/strong\u003e is a \u003cstrong\u003eBaseUnit BU15-P16+A0+2D\u003c\/strong\u003e (BU Type A0) for the \u003cstrong\u003eSIMATIC ET 200SP\u003c\/strong\u003e distributed I\/O system. As a dark BaseUnit, it \u003cstrong\u003eopens a new load-voltage (potential) group\u003c\/strong\u003e and supplies the I\/O module plugged onto it. It features \u003cstrong\u003e16 push-in process terminals\u003c\/strong\u003e for field wiring and is designed for compact, high-density panel layouts.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e BaseUnit BU15-P16+A0+2D, BU Type A0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e SIMATIC ET 200SP Distributed I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e 16 push-in process terminals (no auxiliary terminals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Supply Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e 19.2 V DC to 28.8 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Input Current (L+):\u003c\/strong\u003e 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential Group:\u003c\/strong\u003e Opens a new potential group (2D shared potential)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots:\u003c\/strong\u003e 1 (Type A0 \/ A1 compatible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 15 mm x 117 mm x 35 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 48 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Gauge (Solid\/Flexible):\u003c\/strong\u003e 0.14 mm² to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 °C to +60 °C (horizontal), -30 °C to +50 °C (vertical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (ET 200SP carrier rail)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Protection:\u003c\/strong\u003e 24 V DC \/ 10 A miniature circuit breaker (Type B or C) required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 15 mm width\u003c\/strong\u003e — enables high-density I\/O configurations, reducing panel footprint by up to 60% compared to legacy 40 mm+ base units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-in terminal technology\u003c\/strong\u003e — tool-free wiring with IEC 60947-7-1 compliance, vibration-resistant for automotive and heavy-industry environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew potential group starter\u003c\/strong\u003e — isolates power distribution for the module stack, improving fault isolation and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo auxiliary terminals\u003c\/strong\u003e — cost-optimized for simple I\/O systems where cross-module bridging is unnecessary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Type A0 and A1 I\/O modules\u003c\/strong\u003e — digital inputs, digital outputs, analog I\/O, and combination modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomotive assembly line distributed I\/O nodes\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; beverage packaging and conveyor controls\u003c\/li\u003e\n\u003cli\u003ePharmaceutical batch processing skids\u003c\/li\u003e\n\u003cli\u003eMachine builder OEM platforms with standardized ET 200SP architecture\u003c\/li\u003e\n\u003cli\u003eBrownfield retrofit projects adding decentralized I\/O capacity\u003c\/li\u003e\n\u003cli\u003eHVAC and building management system (BMS) valve\/damper control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify compatibility\u003c\/strong\u003e — confirm your carrier rail is ET 200SP standard; do not mix with ET 200S or older SIMATIC series hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMount on de-energized DIN rail\u003c\/strong\u003e — slide the BaseUnit horizontally onto the ET 200SP carrier rail until an audible click confirms full seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall external protection\u003c\/strong\u003e — place a 24 V DC \/ 10 A miniature circuit breaker (Type B or C) upstream of the L+ supply; this BaseUnit has no internal breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire field devices\u003c\/strong\u003e — use conductors within 0.14–2.5 mm² range; insert into push-in terminals until the audible click is heard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform tug-test and continuity check\u003c\/strong\u003e — gently pull each wire and verify with a multimeter before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall I\/O module\u003c\/strong\u003e — seat the compatible ET 200SP Type A0\/A1 module onto the BaseUnit backplane.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 6BP00-0DA0 and 6BP20-0DA0?\u003c\/strong\u003e\u003cbr\u003e\nA: The 6BP00-0DA0 has \u003cstrong\u003eno auxiliary terminals\u003c\/strong\u003e (A0), while the 6BP20-0DA0 includes \u003cstrong\u003e10 auxiliary terminals\u003c\/strong\u003e (A10) for cross-module signal continuity. Both open a new potential group (2D). Choose 6BP00 for cost-sensitive, simple I\/O builds; choose 6BP20 when auxiliary bridging is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this BaseUnit compatible with ET 200S modules?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e ET 200SP and ET 200S use incompatible backplane standards. Mixing them will cause physical seating failure and electrical damage. Verify all modules carry the ET 200SP family designation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does this BaseUnit have built-in circuit protection?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e An external upstream 24 V DC protection device is mandatory. Omitting it risks catastrophic failure of connected I\/O modules during a surge or short circuit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What conductor gauges are supported?\u003c\/strong\u003e\u003cbr\u003e\nA: Push-in terminals accept solid or flexible conductors from \u003cstrong\u003e0.14 mm² to 2.5 mm²\u003c\/strong\u003e. Using oversized conductors will damage terminal contacts irreparably.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this BaseUnit with Type A1 I\/O modules?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eYes.\u003c\/strong\u003e BU Type A0 BaseUnits accept both Type A0 and Type A1 ET 200SP I\/O modules.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose the \u003cstrong\u003e6BP00-0DA0\u003c\/strong\u003e when your system has \u003cstrong\u003eno auxiliary power requirements\u003c\/strong\u003e and you want the lowest-cost BaseUnit for a new potential group.\u003c\/li\u003e\n\u003cli\u003eIf your I\/O module set includes analog modules or modules requiring auxiliary current, upgrade to the \u003cstrong\u003eA10 variant (6BP20-0DA0)\u003c\/strong\u003e for dedicated 10 A auxiliary capacity.\u003c\/li\u003e\n\u003cli\u003eIf your control logic requires \u003cstrong\u003eisolated power groups\u003c\/strong\u003e (e.g., safety circuits or mixed-potential field devices), select the \u003cstrong\u003e2B variant (6BP20-0BA0)\u003c\/strong\u003e instead of 2D.\u003c\/li\u003e\n\u003cli\u003eAlways verify the exact part number character-by-character against your BOM — 6BP00 vs. 6BP20 and 0BA0 vs. 0DA0 differ by only a few characters but represent entirely different configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53946674249912,"sku":"6ES7193-6BP00-0DA0","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/6ES7193-6BP00-0DA0r180.png?v=1787042119","url":"https:\/\/www.globalpetroparts.com\/products\/siemens-6es7193-6bp00-0da0-simatic-et-200sp-base-unit","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}