{"product_id":"speedtronic-mark-v-uninterruptible-power-supply-board-ds200upsag1agd-ge","title":"Speedtronic Mark V Uninterruptible Power Supply Board DS200UPSAG1AGD GE","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200UPSAG1AGD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the critical Uninterruptible Power Supply (UPS) interface board within the Speedtronic Mark V turbine control system. This board manages the seamless transition between primary AC\/DC power sources and backup battery systems, ensuring the control core remains energized during utility power loss or local grid fluctuations. By regulating the charging and discharging cycles of the backup system, the DS200UPSAG1AGD prevents processor reboots and data loss in the , , and  cores. Utilizing this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal board secures the \"Non-Stop\" operational integrity required for high-availability gas and steam turbines in power generation and petrochemical facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200UPSAG1AGD integrates high-current switching circuits and voltage regulation logic to maintain constant output:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDS200UPSAG1AGD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGeneral Electric (GE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpeedtronic Mark V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUPS Power Management and Battery Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Mark V Cabinet DC\/AC bus inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Rails:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegulated DC power for core backplanes and I\/O logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard high-speed fuses and surge suppression varistors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReal-time battery voltage and current sensor feedback\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProprietary Mark V \"R\" core or power distribution rack mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density ribbon cable headers and heavy-duty screw terminals for power lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe GE DS200UPSAG1AGD provides targeted technical solutions for power stability and system protection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Switching-Time Transition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes high-speed solid-state switching logic to engage backup power instantly. This eliminates voltage dips during a power failure, preventing the turbine control processors from initiating an emergency \"False Trip\" due to momentary power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Battery Charging Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard circuitry monitors the state-of-health and charge levels of the external battery bank. It regulates the charging current to prevent battery over-heating and off-gassing, significantly extending the life of the emergency power storage system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Fault Forensics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DS200UPSAG1AGD communicates power status directly to the Mark V diagnostic system. It identifies low battery voltage, fuse failure, or charging circuit malfunctions, allowing maintenance teams to address power issues before they escalate into a full system shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized EMI Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineers this board with advanced electromagnetic interference (EMI) suppression. This protects the sensitive DC output rails from high-frequency noise generated by nearby generator exciters and high-voltage switchgear, ensuring the CPU receives pure, ripple-free power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200UPSAG1AGD be replaced while the turbine is running?\u003c\/strong\u003eReplacement of the UPS board typically requires a controlled shutdown of the specific core it serves. Because this board handles primary power distribution, removing it will de-energize the associated control logic. Always consult your Mark V maintenance manual for site-specific bypass procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"AGD\" suffix?\u003c\/strong\u003eThe \"AGD\" suffix denotes the specific hardware revision level. This version includes updated component specifications and improved thermal management over earlier revisions. The DS200UPSAG1AGD remains backward compatible with most Mark V systems requiring an UPSA-style board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if the charging circuit is functioning correctly?\u003c\/strong\u003eYou can measure the battery terminal voltage directly at the board's power terminals. If the voltage remains below the nominal float charge level while the cabinet power is on, the onboard charging transistors or the primary fuse may require inspection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is buying \"Brand New\" original stock essential for UPS boards?\u003c\/strong\u003eUPS boards contain high-stress power components, including transformers and large capacitors, which degrade due to constant thermal cycling. Refurbished units often hide latent component fatigue that leads to failure during an actual power emergency. Only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits guarantee the reliability needed to protect multi-million dollar turbine assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53450669686968,"sku":"DS200UPSAG1AGD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200UPSAG1AGD_3_1.jpg?v=1778314455","url":"https:\/\/www.globalpetroparts.com\/products\/speedtronic-mark-v-uninterruptible-power-supply-board-ds200upsag1agd-ge","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}