{"product_id":"sst-pb3-clx-rll-allen-bradley-controllogix-profibus-dp-communication-module","title":"SST-PB3-CLX-RLL | Allen-Bradley | ControlLogix Profibus DP Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSST-PB3-CLX-RLL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Profibus DP communication interface specifically designed for the Allen-Bradley ControlLogix 1756 platform. This in-chassis module enables seamless data exchange between the Logix backplane and Profibus DP field devices. It serves as a critical bridge for hybrid automation environments, allowing a ControlLogix CPU to master distributed I\/O, drives, and instrumentation on a Profibus network. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock to ensure maximum network stability and compliance with industrial communication standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe SST-PB3-CLX-RLL occupies a single slot and provides robust throughput for high-density I\/O configurations:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DPV0 Master\/Slave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley ControlLogix; Honeywell PlantScape\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speeds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6K to 12M baud (Auto-sensing supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 125 DP Slaves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 256 I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e122 Words\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e850 mA @ 5V DC; 1.75 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 9-pin Sub-D (Female)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum 8 modules per rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe SST-PB3-CLX-RLL addresses complex integration challenges in multi-vendor automation environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports transmission rates up to 12 Mbaud. This ensures rapid update times for motion control and critical interlocking logic across the Profibus network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Slot Placement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou can install the module in any available slot of a local or remote 1756 ControlLogix chassis. This flexibility simplifies hardware layout in crowded control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Slave Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single module manages up to 125 DP slaves. This high density reduces the number of required communication cards, lowering the overall hardware footprint and power consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe RLL (Remote Ladder Logic) support allows for streamlined data mapping. It eliminates complex messaging blocks, allowing the ControlLogix processor to treat Profibus I\/O as native tags.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SST-PB3-CLX-RLL operate as a Profibus Slave?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While engineers primarily use this module as a DP Master to control field devices, it also supports DPV0 Slave functionality. This allows a ControlLogix system to appear as a high-level I\/O device to another master controller, such as a Siemens S7 PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable is required for the network connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module utilizes a standard 9-pin D-Sub female connector. You must use a shielded, twisted-pair Profibus-certified cable with appropriate termination resistors at both ends of the segment to prevent signal reflection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle Honeywell PlantScape integration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SST-PB3-CLX-RLL carries specific compatibility for Honeywell PlantScape systems. It integrates directly into the PlantScape architecture through the ControlLogix backplane, enabling Honeywell controllers to access Profibus instrument data without external third-party gateways.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit a refurbished or used component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We guarantee that every SST-PB3-CLX-RLL shipped is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand remains in its original manufacturer packaging. This ensures the 850 mA backplane power draw and internal communication ASICs meet original factory tolerances.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53423040463032,"sku":"SST-PB3-CLX-RLL","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/SST-PB3-CLX.jpg?v=1777539982","url":"https:\/\/www.globalpetroparts.com\/products\/sst-pb3-clx-rll-allen-bradley-controllogix-profibus-dp-communication-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}