{"product_id":"t8314-ics-triplex-trusted-fibre-tx-rx-communications-unit","title":"T8314 ICS Triplex Trusted Fibre TX\/RX Communications Unit","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eICS Triplex T8314\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the essential optical interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTrusted™ Triple Modular Redundancy (TMR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. It facilitates high-speed, point-to-point fiber optic communication between Trusted Controller chassis and Expander chassis. By converting electronic signals into optical pulses, the T8314 extends the physical reach of the safety system while maintaining the strict timing requirements of a fault-tolerant architecture. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring your safety network maintains peak performance without the risks associated with used hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Optic Transmitter\/Receiver (TX\/RX)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrusted™ TMR System Expander Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Media\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-mode Fiber Optic Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-bandwidth synchronized system bus speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDistance Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 500 meters (typical for multi-mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandardized optical ports for secure latching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLink status and port activity LED indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating (Optional)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable in T8314C (Conformal Coated) version\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Ground Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy using fiber optic media, the T8314 provides total electrical isolation between chassis. This prevents ground potential differences from damaging sensitive electronics in distributed control architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaster Long-Distance Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module allows engineers to locate Expander racks up to 500 meters away from the Main Controller. This is critical for large-scale facilities like refineries or offshore platforms where I\/O must be placed close to the field equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmunize Data Against EMI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike copper-based communication, the optical signals in the T8314 remain completely unaffected by high-voltage equipment, motors, or radio frequency interference (RFI), ensuring zero data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplify System Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs provide instant visual confirmation of link integrity. This allows maintenance teams to quickly distinguish between a network failure and a hardware fault, reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the T8314 with copper-based expander interfaces?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Trusted system requires matched interface types for each link. If you utilize the T8314 at the Controller end, you must use a compatible Fiber RX unit at the Expander end to maintain the high-speed TMR bus integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the T8314 and the T8314C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe T8314C is the \"Conformal Coated\" version of the standard T8314. It features an additional protective layer on the PCB to resist moisture, salt spray, and atmospheric contaminants in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the T8314 support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, you can replace the T8314 while the system is powered. However, removing a communication module will temporarily break the link to the associated expander rack; the TMR system will handle this according to your safety logic configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit \"100% Brand New\" or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this T8314 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory stock\u003c\/strong\u003e. It has never been installed or used in a production environment, ensuring maximum reliability for your safety-critical system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53418071457976,"sku":"T8314","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/T8314_3.jpg?v=1777430905","url":"https:\/\/www.globalpetroparts.com\/products\/t8314-ics-triplex-trusted-fibre-tx-rx-communications-unit","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}