{"product_id":"t8403-ics-triplex-trusted-series-24-vdc-digital-input-module","title":"T8403 | ICS Triplex Trusted Series | 24 VDC Digital Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eICS Triplex T8403\u003c\/strong\u003e Digital Input Module is part of the Trusted TMR (Triple Modular Redundancy) system, designed to deliver fault-tolerant digital input acquisition for safety-critical applications. Operating at 24 VDC, the module provides reinforced field isolation, configurable thresholds, and precise event resolution, making it suitable for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ICS Triplex\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003eT8403\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Digital Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField Common Isolation\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e50 V reinforced (continuous)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e250 V basic (fault condition)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType tested at 2436 VDC for 60 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e: None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e: None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 5 kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: –6 VDC to +36 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThresholds\u003c\/strong\u003e: Configurable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Withstanding Voltage\u003c\/strong\u003e: ±50 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Accuracy\u003c\/strong\u003e: 0.5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntrinsic Safety\u003c\/strong\u003e: Not included (external barrier required)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSequence of Events\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvent Resolution (LSB): 1 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTimestamp Accuracy: ±10 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Temperature: 0 °C to +60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStorage Temperature: –25 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelative Humidity: 10%–95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeight: 266 mm (10.5 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidth: 31 mm (1.2 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepth: 303 mm (12.0 in)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.18 kg (2.6 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReinforced isolation for field common connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigurable input thresholds for flexible integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-resolution event logging with 1 ms resolution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundant safety architecture with TMR design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRugged construction for industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety instrumented systems requiring precise digital input monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation and chemical processing plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAerospace and defense systems with strict reliability requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed control systems where event resolution and timestamp accuracy are critical.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the T8403 provide channel-to-channel isolation?\u003c\/strong\u003e  A: No, channel-to-channel isolation is not included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is intrinsic safety supported?\u003c\/strong\u003e  A: No, external barriers are required for intrinsic safety compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the event resolution capability?\u003c\/strong\u003e  A: The module records events with 1 ms resolution and ±10 ms timestamp accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the module withstand voltage surges?\u003c\/strong\u003e  A: Yes, it can withstand up to ±50 VDC.\u003c\/span\u003e\u003c\/p\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":52852510589112,"sku":"T8403","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/T8403.jpg?v=1770970099","url":"https:\/\/www.globalpetroparts.com\/products\/t8403-ics-triplex-trusted-series-24-vdc-digital-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}