{"product_id":"triconex-analogue-input-ta-16-channel-dual-isolated-9832","title":"Triconex Analogue input TA, 16 channel, dual, isolated 9832","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eanalog input module provides high-precision signal acquisition for Tricon safety instrumented systems in industrial environments.\u003cbr\u003eIt supports 16-channel dual isolated architecture, ensuring accurate measurement of voltage and current signals.\u003cbr\u003eAdditionally, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates seamlessly with Tricon systems, enabling stable and reliable real-time data processing.\u003cbr\u003eEngineers choose the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor its accuracy, isolation design, and long-term operational stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eTriconex (Invensys \/ Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module (TA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTricon Safety Instrumented System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eDual isolated architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage and current signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0–5 V, 0–10 V, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eHigh precision industrial-grade measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eFast real-time signal acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eHigh impedance for stable measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Protection\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics Capability\u003c\/td\u003e\n\u003ctd\u003eContinuous channel monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Source\u003c\/td\u003e\n\u003ctd\u003eTricon backplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow-power optimized design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eBackplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Design\u003c\/td\u003e\n\u003ctd\u003eMulti-layer industrial PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 300 mm × 200 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5–2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eChannel status and diagnostics LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive chassis airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eCompatible with Tricon fault-tolerant systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eIndustrial electromagnetic standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eRack-mounted single-slot design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eMinimal maintenance required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Scope\u003c\/td\u003e\n\u003ctd\u003eProcess control, safety monitoring, industrial automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003csection\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the 9832 module?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule collects and converts analog signals into digital data for Tricon systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many channels does the 9832 support?\u003c\/strong\u003e\u003cbr\u003eA2: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 16 dual isolated analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What signal types does the 9832 support?\u003c\/strong\u003e\u003cbr\u003eA3: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports voltage and current signals, including 0–10 V and 4–20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does the 9832 include isolation protection?\u003c\/strong\u003e\u003cbr\u003eA4: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes dual isolation to reduce interference and improve measurement safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is the 9832 available in stock?\u003c\/strong\u003e\u003cbr\u003eA5: We supply brand-new original\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9832\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules and maintain stock for fast delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What shipping and return services do you provide?\u003c\/strong\u003e\u003cbr\u003eA6: We ship via DHL and similar carriers within 3 days to 2 weeks and support 30-day returns for quality issues.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53291460657336,"sku":"9832","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TriconexAnalogueinputTA_16channel_dual_isolated9832_3.jpg?v=1776051433","url":"https:\/\/www.globalpetroparts.com\/products\/triconex-analogue-input-ta-16-channel-dual-isolated-9832","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}