{"product_id":"tsxetg100-schneider-modicon-quantum-connexium-ethernet-modbus-gateway-router","title":"TSXETG100 | Schneider Modicon Quantum | ConneXium Ethernet Modbus Gateway\/Router","description":"\u003ch3\u003eSchneider Electric TSXETG100 ConneXium Ethernet Modbus Gateway\/Router — 10\/100Mbps, Class B10, PoE\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTSXETG100\u003c\/strong\u003e is a \u003cstrong\u003eConneXium Ethernet Modbus gateway\/router\u003c\/strong\u003e manufactured by Schneider Electric under the \u003cstrong\u003eTelemecanique\u003c\/strong\u003e brand. It bridges \u003cstrong\u003eModbus RTU\/ASCII serial devices\u003c\/strong\u003e to \u003cstrong\u003eEthernet TCP\/IP networks\u003c\/strong\u003e, enabling legacy Modbus equipment to integrate into modern industrial Ethernet infrastructures. The device features a \u003cstrong\u003eClass B10 web server\u003c\/strong\u003e for diagnostics, \u003cstrong\u003eSNMP agent\u003c\/strong\u003e for device management, and supports \u003cstrong\u003ePower over Ethernet (PoE IEEE 802.3af)\u003c\/strong\u003e for flexible power options.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric (Telemecanique brand)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ConneXium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Ethernet Modbus Gateway\/Router\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 × RJ45, 10BASE-T\/100BASE-TX (auto-negotiation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e1 × RS-485 (5-way removable terminal block), Modbus RTU\/ASCII, 57.6 kbps\u003c\/li\u003e\n\u003cli\u003e1 × RS-232 (RJ45), 38.4 kbps\u003c\/li\u003e\n\u003cli\u003e1 × RS-485 (micro switches), Modbus RTU\/ASCII, 57.6 kbps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Modbus Devices:\u003c\/strong\u003e ≤ 32 on serial link\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Server:\u003c\/strong\u003e Class B10 (diagnostics on Ethernet and Modbus links, connected products list, Modbus register read)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Services:\u003c\/strong\u003e BOOTP protocol, FDR client, SNMP agent, miniature onboard firewall (IP address filtering), password protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC (±10%) or PoE IEEE 802.3af\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ~2.5–4 W (varies by source)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -20°C to +80°C (-4°F to +176°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Symmetrical DIN rail (35 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 72 mm (W) × 81 mm (H) × 76 mm (D) [2.83 × 3.19 × 3.00 in]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.16–0.34 kg (varies by source; 0.34 kg most common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet: LK (link), RX, TX, 100 (speed)\u003c\/li\u003e\n\u003cli\u003eSerial: RS485 (mode), RX, TX\u003c\/li\u003e\n\u003cli\u003ePower\/Status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass I Division 2:\u003c\/strong\u003e Compliant (Groups A, B, C, D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e \u003cstrong\u003eObsolete \/ Discontinued\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement:\u003c\/strong\u003e EcoStruxure Panel Server product line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eArchitecture \u0026amp; Functionality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent Ready:\u003c\/strong\u003e Schneider Electric's concept for seamless integration and communication between connected devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Conversion:\u003c\/strong\u003e Converts Modbus RTU\/ASCII serial frames to Modbus TCP\/IP Ethernet packets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Diagnostics:\u003c\/strong\u003e Predefined web pages for Ethernet link status, Modbus communication diagnostics, and connected device monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e Onboard firewall with IP address filtering and password protection prevents unauthorized access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Management:\u003c\/strong\u003e SNMP agent enables centralized monitoring and administration via SNMP manager\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFDR Client:\u003c\/strong\u003e Faulty Device Replacement service for automatic device recovery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoE Support:\u003c\/strong\u003e Can be powered via Ethernet cable (IEEE 802.3af) or external 24 VDC supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the TSXETG100 on a \u003cstrong\u003e35 mm symmetrical DIN rail\u003c\/strong\u003e in the control cabinet.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003e24 VDC power\u003c\/strong\u003e to the control power terminal (or use PoE if switch supports IEEE 802.3af).\u003c\/li\u003e\n\u003cli\u003eConnect the \u003cstrong\u003eRJ45 Ethernet port\u003c\/strong\u003e to the 10\/100 Mbps network switch using standard Cat 5e\/6 cable.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003eModbus RTU\/ASCII serial devices\u003c\/strong\u003e to the RS-485 terminal block (5-way removable) or RS-232 RJ45 port.\u003c\/li\u003e\n\u003cli\u003eConfigure \u003cstrong\u003eEthernet settings\u003c\/strong\u003e (IP address, subnet mask, gateway) via web browser using an Ethernet crossover cable, or via HyperTerminal using a null modem cable (TCSEAK0100 configuration kit sold separately).\u003c\/li\u003e\n\u003cli\u003eConfigure \u003cstrong\u003eserial port parameters\u003c\/strong\u003e (baud rate, parity, stop bits) to match connected Modbus devices.\u003c\/li\u003e\n\u003cli\u003eConfigure the \u003cstrong\u003edevice list\u003c\/strong\u003e (Modbus slave addresses mapped to IP addresses).\u003c\/li\u003e\n\u003cli\u003eVerify \u003cstrong\u003eLED indicators\u003c\/strong\u003e: LK (link active), Ethernet RX\/TX, Serial RX\/TX.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is TSXETG100 still in production?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e The TSXETG100 and EGX100 are \u003cstrong\u003eobsolete\u003c\/strong\u003e. Schneider Electric recommends the \u003cstrong\u003eEcoStruxure Panel Server\u003c\/strong\u003e product line as the replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between TSXETG100 and EGX100?\u003c\/strong\u003e\u003cbr\u003eA: Both are physically identical but branded differently. \u003cstrong\u003eEGX100\u003c\/strong\u003e (Square D brand) supports \u003cstrong\u003eModbus RTU, Jbus, PowerLogic (SY\/MAX), and Modbus ASCII\u003c\/strong\u003e. \u003cstrong\u003eTSXETG100\u003c\/strong\u003e (Telemecanique brand) supports only \u003cstrong\u003eModbus RTU and Modbus ASCII\u003c\/strong\u003e. PowerLogic legacy devices (CM100\/200, CM2000) and SEPAM relays cannot communicate through TSXETG100.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can TSXETG100 be powered by PoE?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eYes.\u003c\/strong\u003e The device supports \u003cstrong\u003ePower over Ethernet (IEEE 802.3af)\u003c\/strong\u003e via the RJ45 Ethernet port, eliminating the need for a separate 24 VDC power supply if the switch supports PoE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Modbus devices can connect to TSXETG100?\u003c\/strong\u003e\u003cbr\u003eA: Up to \u003cstrong\u003e32 Modbus serial devices\u003c\/strong\u003e on a single RS-485 network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is Class B10 web server?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eClass B10\u003c\/strong\u003e is Schneider Electric's classification for embedded web servers with predefined diagnostic pages, device lists, and Modbus register read access. It does not support custom web page development.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is TSXETG100 compatible with Windows 10\/11?\u003c\/strong\u003e\u003cbr\u003eA: The TSXETG100 is a standalone gateway and does not require a specific Windows version. However, the configuration tools referenced in legacy documentation support Windows XP, Vista, Server 2003\/2008 R2, and Windows 7. Modern browsers can access the web server directly.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Modbus to Ethernet gateway:\u003c\/strong\u003e TSXETG100 (if existing stock available)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement for new installations:\u003c\/strong\u003e \u003cstrong\u003eEcoStruxure Panel Server\u003c\/strong\u003e series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerLogic\/SY\/MAX compatibility:\u003c\/strong\u003e Use EGX100 (also obsolete) instead of TSXETG100\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Serial protocol (Modbus RTU vs ASCII), baud rate, number of devices, and Ethernet network configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsider PoE:\u003c\/strong\u003e If your switch supports IEEE 802.3af, PoE eliminates separate power wiring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53736484503736,"sku":"TSXETG100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TSXETG100.png?v=1783584542","url":"https:\/\/www.globalpetroparts.com\/products\/tsxetg100-schneider-modicon-quantum-connexium-ethernet-modbus-gateway-router","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}