{"product_id":"ur5fh-ge-multilin-ur-series-ur-5fh-transducer-i-o-5f-module","title":"UR5FH | GE Multilin UR Series UR 5FH Transducer I\/O 5F Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-5FH\u003c\/strong\u003e is a \u003cstrong\u003eTransducer I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module enables signal conversion from \u003cstrong\u003e–1 to +20 mA DC\u003c\/strong\u003e into digital format, allowing the relay to display scaled, real-time parameters. The UR-5FH is used to monitor system parameters such as \u003cstrong\u003etemperature, vibration, pressure, wind speed, and flow\u003c\/strong\u003e by converting analog transducer signals into digital data that the UR relay can process and display.\u003c\/p\u003e\n\n\u003cp\u003eThe module's I\/O functions — including \u003cstrong\u003eDCmA, RTD, and RRTD inputs\/outputs\u003c\/strong\u003e — are configurable via the relay's keypad and LCD interface or through \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software. The UR-5FH is an essential component for applications requiring analog signal integration into digital protection and control systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDCmA input\/output\u003c\/strong\u003e conversion: –1 to +20 mA DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRTD (Resistance Temperature Detector)\u003c\/strong\u003e input support for temperature monitoring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRRTD (Remote RTD)\u003c\/strong\u003e input capability for distributed temperature sensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalog output\u003c\/strong\u003e for hardened connections to SCADA, PLC, or HMI devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable I\/O functions\u003c\/strong\u003e via keypad\/LCD or EnerVista UR software\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and upgrades\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTransducer I\/O Module (Order Code: 5F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDCmA Input Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–1 to +20 mA DC\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRTD Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported (temperature monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRRTD Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSupported (remote temperature sensing)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAnalog Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAvailable for SCADA\/PLC\/HMI integration\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eKeypad\/LCD or \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature monitoring\u003c\/strong\u003e — transformer winding, motor bearing, and generator stator temperatures\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration monitoring\u003c\/strong\u003e — turbine and rotating machinery health assessment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure monitoring\u003c\/strong\u003e — hydraulic and pneumatic system control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow monitoring\u003c\/strong\u003e — cooling water and lubrication systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWind speed monitoring\u003c\/strong\u003e — wind turbine and environmental sensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA\/PLC integration\u003c\/strong\u003e — analog signal conversion for centralized monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-5FH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It integrates seamlessly with other UR modules including CPU, CT\/VT, digital I\/O, and communication modules. Always verify firmware compatibility when adding transducer I\/O modules to existing systems.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-5FH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Wiring:\u003c\/strong\u003e Connect RTD, DCmA, and analog output wiring per the UR series wiring diagram.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure transducer scaling and alarm thresholds via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software or the front panel keypad.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"5F\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: The \"5F\" designates a \u003cstrong\u003etransducer I\/O module\u003c\/strong\u003e with DCmA, RTD, and RRTD input\/output capabilities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What types of sensors can be connected to the UR-5FH?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-5FH supports \u003cstrong\u003eRTD temperature sensors, DCmA transducers (4–20 mA), and remote RTD (RRTD)\u003c\/strong\u003e inputs for distributed temperature monitoring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the UR-5FH provide analog outputs to SCADA systems?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The module includes \u003cstrong\u003eanalog outputs\u003c\/strong\u003e that can be hardwired to SCADA, PLC, or HMI devices for remote monitoring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-5FH\u003c\/strong\u003e when you need \u003cstrong\u003eDCmA, RTD, and RRTD transducer I\/O\u003c\/strong\u003e for analog parameter monitoring.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003edigital I\/O only\u003c\/strong\u003e, consider the UR-6 series modules (UR-6CH, UR-6HH, UR-6TH).\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eCT\/VT analog inputs\u003c\/strong\u003e, consider the UR-8 series modules.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-5FH \/ UR5FH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Transducer I\/O Module — DCmA\/RTD\/RRTD Inputs \u0026amp; Outputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759567233208,"sku":"UR5FH","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6EV_2.png?v=1783925597","url":"https:\/\/www.globalpetroparts.com\/products\/ur5fh-ge-multilin-ur-series-ur-5fh-transducer-i-o-5f-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}