{"product_id":"ur7jv-ge-multilin-ur-7jv-protection-relay-module","title":"UR7JV | GE Multilin UR 7JV Protection Relay Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-7JV\u003c\/strong\u003e is a \u003cstrong\u003eProtection Relay Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module safeguards critical electrical assets such as \u003cstrong\u003efeeders, transformers, and motors\u003c\/strong\u003e, delivering comprehensive protection functions including \u003cstrong\u003eovercurrent, undervoltage, overload, and motor protection\u003c\/strong\u003e. Engineered for industrial-grade reliability, the UR-7JV ensures safe, efficient, and reliable operation in utility and industrial power systems.\u003c\/p\u003e\n\n\u003cp\u003eThe module supports \u003cstrong\u003eModbus TCP\/IP communication\u003c\/strong\u003e, enabling seamless integration with \u003cstrong\u003edistributed control systems (DCS)\u003c\/strong\u003e and \u003cstrong\u003eprogrammable logic controllers (PLC)\u003c\/strong\u003e. Its rugged, industrial-grade design provides high reliability in harsh environmental conditions, while \u003cstrong\u003eevent recording and diagnostic features\u003c\/strong\u003e enhance fault visibility and system uptime.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive protection elements:\u003c\/strong\u003e Overcurrent, undervoltage, overload, and motor protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModbus TCP\/IP communication\u003c\/strong\u003e for easy DCS\/PLC integration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEvent reports and fault recordings\u003c\/strong\u003e for troubleshooting and system improvements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible functionality\u003c\/strong\u003e — protects feeders, transformers, and motors from electrical issues\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental durability\u003c\/strong\u003e — built to endure harsh industrial conditions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and system upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e for configuration and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProtection Relay Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProtection Functions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOvercurrent, Undervoltage, Overload, Motor Protection\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCommunication Protocol\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e100 mm × 80 mm × 20 mm\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eMotor and transformer protection systems\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eFeeder and busbar protection\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eSubstation automation and control\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eIndustrial process and power distribution networks\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA integration\u003c\/strong\u003e — remote monitoring and control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-7JV is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. It integrates seamlessly with other UR modules including CPU, CT\/VT, digital I\/O, and communication modules. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded electrostatic discharge (ESD) wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module's physical orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-7JV into the chassis guide rails, aligning the rear terminal block with the backplane connector. Push firmly until the faceplate sits flush.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Observe correct polarity for all connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on the relay and configure protection settings via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software or the front panel keypad\/LCD.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection functions does the UR-7JV provide?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-7JV provides \u003cstrong\u003eovercurrent, undervoltage, overload, and motor protection\u003c\/strong\u003e functions to safeguard critical electrical assets.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocol does the UR-7JV support?\u003c\/strong\u003e\u003cbr\u003e\nA: The UR-7JV supports \u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e for seamless integration with DCS and PLC systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the UR-7JV be used for transformer protection?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The UR-7JV is designed to protect \u003cstrong\u003efeeders, transformers, and motors\u003c\/strong\u003e from electrical issues.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What software is required for configuration?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e is the official GE software for configuring, monitoring, and diagnosing all UR series modules.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-7JV\u003c\/strong\u003e when you need a \u003cstrong\u003ecompact protection relay module\u003c\/strong\u003e with overcurrent, undervoltage, overload, and motor protection capabilities.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003ecommunication modules with RS485 and Ethernet\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-7JH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003edigital I\/O expansion\u003c\/strong\u003e, consider the UR-6 series modules (UR-6CH, UR-6HH, UR-6TH).\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e to confirm the exact module configuration before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-7JV \/ UR7JV\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Protection Relay Module — Overcurrent, Undervoltage, Overload, Motor Protection, Modbus TCP\/IP\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759658361016,"sku":"UR7JV","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR7JV_2.png?v=1783925654","url":"https:\/\/www.globalpetroparts.com\/products\/ur7jv-ge-multilin-ur-7jv-protection-relay-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}