{"product_id":"westinghouse-ovation-5x00109g02-hart-high-performance-analog-input-module","title":"Westinghouse Ovation 5X00109G02 Hart High Performance Analog Input Module","description":"\u003ch3\u003eProduct Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 5X00109G02\u003c\/strong\u003e is a \u003cstrong\u003ePMOD Analog Input Module\u003c\/strong\u003e for the Emerson Ovation distributed control system (DCS). It provides \u003cstrong\u003e8 channels of HART high-performance analog input\u003c\/strong\u003e with \u003cstrong\u003ecurrent limiting protection\u003c\/strong\u003e, enabling precise process variable acquisition from smart field transmitters while protecting the module from overload conditions.\u003c\/p\u003e\n\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 5X00109G02\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e PMOD Analog Input Module (8-Channel HART High-Performance)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 analog inputs (per Emerson documentation); some suppliers list 2 channels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 4–20 mA DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit (per supplier documentation)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e Integrated per-channel current limiting for overload protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHART Protocol:\u003c\/strong\u003e HART 5\/6\/7 compatible\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 250 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 134 × 173 × 40 mm (per some suppliers)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.2 kg (per some suppliers)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson (formerly Westinghouse)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8-channel high-performance HART analog input for smart transmitter integration\u003c\/li\u003e\n  \u003cli\u003eIntegrated current limiting protects module from field-side overloads\u003c\/li\u003e\n  \u003cli\u003eHART digital communication for device configuration and diagnostics\u003c\/li\u003e\n  \u003cli\u003e16-bit resolution for precise process variable measurement\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard 4-20mA and HART-enabled field devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C (per supplier documentation)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0% to 95% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the 5X00109G02 used for?\u003c\/h4\u003e\n\u003cp\u003eIt is an 8-channel HART high-performance analog input module for Emerson Ovation DCS, acquiring 4-20mA signals from smart field transmitters with integrated current limiting protection.\u003c\/p\u003e\n\n\u003ch4\u003eHow many channels does the 5X00109G02 have?\u003c\/h4\u003e\n\u003cp\u003eEmerson documentation indicates \u003cstrong\u003e8 channels\u003c\/strong\u003e. Some suppliers list 2 channels — verify exact configuration with your supplier before ordering.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is current limiting?\u003c\/h4\u003e\n\u003cp\u003eIntegrated \u003cstrong\u003eper-channel current limiting\u003c\/strong\u003e restricts current flow during overload conditions, protecting the module from damage due to short circuits or wiring faults.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the difference between 5X00109G02 and 5X00106G01?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003e5X00109G02\u003c\/strong\u003e is a PMOD (Personality Module) with current limiting. The \u003cstrong\u003e5X00106G01\u003c\/strong\u003e is an EMOD (Electronics Module) HART high-performance analog input without current limiting.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003ch4\u003eSafety Precautions\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-energize the Ovation rack before installation\u003c\/li\u003e\n  \u003cli\u003eUse proper ESD protection when handling the module\u003c\/li\u003e\n  \u003cli\u003eVerify field device signal type and range before wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStep-by-Step Procedure\u003c\/h4\u003e\n\u003col\u003e\n  \u003cli\u003ePower down the Ovation I\/O rack\u003c\/li\u003e\n  \u003cli\u003eAlign the module with the rack slot and insert firmly\u003c\/li\u003e\n  \u003cli\u003eSecure the module retaining clips\u003c\/li\u003e\n  \u003cli\u003eConnect 4-20mA field wiring to the terminal base unit\u003c\/li\u003e\n  \u003cli\u003ePower up and verify module status LEDs\u003c\/li\u003e\n  \u003cli\u003eConfigure HART device parameters via Ovation engineering station\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify channel count (8 vs 2) with your supplier before ordering\u003c\/li\u003e\n  \u003cli\u003eConfirm HART protocol version compatibility with your field devices\u003c\/li\u003e\n  \u003cli\u003eFor applications requiring current limiting protection, select 5X00109G02 over 5X00106G01\u003c\/li\u003e\n  \u003cli\u003eEnsure 250 Ω loop resistance for proper HART communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated Part Numbers\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5X00106G01 — EMOD HART Analog Input Module, High Performance (8-channel, no current limiting)\u003c\/li\u003e\n  \u003cli\u003e5X00109G01 — PMOD Analog Input Module, HART High Performance (earlier revision)\u003c\/li\u003e\n  \u003cli\u003e5X00109G02 — PMOD Analog Input Module, HART High Performance with Current Limiting (this part)\u003c\/li\u003e\n  \u003cli\u003e5X00058G01 — HART Analog Input Module (standard)\u003c\/li\u003e\n  \u003cli\u003e5X00070G01 — 4-20mA Analog Input Module, High Speed\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53684558725304,"sku":"5X00109G02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5X00059G01_2.png?v=1782979612","url":"https:\/\/www.globalpetroparts.com\/products\/westinghouse-ovation-5x00109g02-hart-high-performance-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}