{"product_id":"westinghouse-ovation-5x00119g03-rtd-input-module-8ch","title":"Westinghouse Ovation 5X00119G03 RTD Input Module 8CH","description":"\u003ch3\u003eEmerson Ovation 5X00119G03 – 8-Channel High-Precision RTD Input Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 5X00119G03\u003c\/strong\u003e is an \u003cstrong\u003e8-channel high-precision RTD input module\u003c\/strong\u003e for advanced temperature measurement in the Ovation DCS. It builds upon the G02 revision with enhanced diagnostics, wider compatibility, and integrated cold-junction compensation for thermocouple adapters.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 RTD inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported RTD Types:\u003c\/strong\u003e Pt100 (−200°C to +850°C), Pt500, Pt1000, Cu50, Cu100\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e 0.1% of span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit A\/D conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Configuration:\u003c\/strong\u003e 2-wire, 3-wire, 4-wire RTD support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Integrated (for TC adapter use)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 50 Hz acquisition mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Real-time open\/short sensor detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel and input-to-system isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0–95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 41 mm × 159 mm × 108 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5X00119G03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8-Channel High-Precision RTD Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt500, Pt1000, Cu50, Cu100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range\u003c\/td\u003e\n\u003ctd\u003e−200°C to +850°C (Pt100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Config\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen\/short detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range\u003c\/td\u003e\n\u003ctd\u003e−40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eG03 Improvements Over G02\u003c\/strong\u003e\u003cbr\u003eG03 adds enhanced diagnostics, wider RTD type support (Cu50\/Cu100), and improved isolation. It is the recommended choice for new installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCryogenic Temperature Limits\u003c\/strong\u003e\u003cbr\u003eThe lower limit for Pt100 is −200°C. Cryogenic applications below this limit require specialized cryogenic RTDs or diodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-Wire RTD Necessity\u003c\/strong\u003e\u003cbr\u003e4-wire eliminates lead resistance errors. It is recommended for high-precision (below 0.5°C error) or long cable runs above 100 m. 3-wire is sufficient for most industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Thermocouple Support\u003c\/strong\u003e\u003cbr\u003eThe module is RTD-only. With an external cold-junction compensation box, some configurations accept thermocouple inputs. For native thermocouple support, use dedicated TC modules (e.g., 1C31116G04).\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Insert 5X00119G03 into the Ovation RTD slot. Follow anti-static precautions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Wire RTDs to the terminal block. For 3-wire Pt100, connect the red lead to excitation +, and the two white leads to excitation − and sense terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e In Ovation Developer Studio, select RTD type, wire mode, and temperature range. Enable open-circuit and short-circuit alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e Configure channel scaling (°C, °F, or Kelvin) and alarm setpoints (Hi\/Lo, HiHi\/LoLo).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Validate with an ice bath (0.00°C) and boiling point reference (100.00°C at sea level) for process-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cp\u003eChoose \u003cstrong\u003e5X00119G03\u003c\/strong\u003e for \u003cstrong\u003enew Ovation temperature monitoring projects\u003c\/strong\u003e requiring 8-channel RTD input with premium diagnostics. It is the upgrade path from legacy 1C31161G02. For 16-channel density, use 5X00120G02. For thermocouple sensors (Type K, J, T), select a dedicated thermocouple input module.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53864850227384,"sku":"5X00119G03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5X00119G03.png?v=1785815293","url":"https:\/\/www.globalpetroparts.com\/products\/westinghouse-ovation-5x00119g03-rtd-input-module-8ch","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}