{"product_id":"woodward-8440-2150-ls-5-v2-circuit-breaker-control-module","title":"Woodward 8440-2150 LS-5 V2 Circuit Breaker Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003eHigh-Performance Synchronization and Breaker Management\u003c\/h3\u003e\n\u003cp\u003eThe Woodward\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated LS-5 V2 series control module designed to manage and protect circuit breakers in complex power distribution systems. This unit provides comprehensive synchronization check (sync-check), mains decoupling, and advanced breaker management for generator-to-grid or generator-to-generator interconnections. Engineered for high-availability environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component for distributed generation, microgrids, and industrial facilities where precise control of incoming and outgoing breakers is required to maintain system stability.\u003c\/p\u003e\n\u003ch3\u003eGrid Compliance and Advanced Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe LS-5 V2 series is recognized for its strict adherence to international grid codes, including VDE AR-N 4105 and BDEW. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes True RMS sensing to provide accurate electrical measurements, unaffected by non-linear loads or harmonics. It features integrated QV (Reactive Power\/Voltage) and time-dependent voltage monitoring to ensure the system reacts correctly to grid disturbances. Whether operating as a stand-alone unit or integrated with Woodward easYgen-3000XT series controllers via CAN bus, this module provides the deterministic logic necessary for secure mains decoupling and re-synchronization.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following technical data details the electrical and functional capabilities of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8444-2150\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e8440-2150\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLS-5 V2 (Circuit Breaker Control)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\/24 VDC (8.0 VDC to 40.0 VDC operational)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.25 × V-rated (Linear sensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensing Technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrue RMS for Voltage and Current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN bus and RS-485 interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInputs\/Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFreely configurable discrete inputs and relay outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable vector groups and sync-check window\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Scalability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 LS-5 units per application (32 bus segments)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard modular housing for door or DIN-rail mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e998g (1.0 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, VDE AR-N 4105, BDEW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52528903585976,"sku":"8440-2150","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/199..jpg?v=1770196080","url":"https:\/\/www.globalpetroparts.com\/products\/woodward-8440-2150-ls-5-v2-circuit-breaker-control-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}