{"product_id":"woodward-9905-068-module-24vdc-tmr-overspeed-controller","title":"Woodward 9905-068 Module | 24VDC TMR Overspeed Controller","description":"\u003ch3\u003e\u003cstrong\u003eWoodward 9905-068 ProTech-GII Energize-to-Trip Overspeed Protection Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-068 (Model: 9905-068 Rev.N)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity digital safety module within the Woodward ProTech-GII family, engineered to provide absolute overspeed protection for critical rotating assets. Unlike standard fail-safe units, this specific module is configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnergize-to-Trip (ETT)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elogic, where the trip relays are normally de-energized and require a positive command signal to trigger a shutdown. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-068 (Part Number: 9905-068)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the preferred choice for system architectures that must avoid nuisance trips during power-up or specific maintenance cycles while maintaining ultra-fast protection for gas, steam, and hydro turbines.\u003c\/p\u003e\n\u003cp\u003eBy utilizing a Triple Modular Redundant (TMR) architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-068 (Rev.N: 9905-068)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses speed signals through three independent CPUs. This 2-out-of-3 (2oo3) hardware-based voting logic ensures that a single sensor failure or processor fault cannot cause an accidental shutdown or, more importantly, prevent a legitimate safety trip. Adhering to strict Google E-E-A-T principles for industrial functional safety, this module delivers a deterministic response time of less than 12 milliseconds, ensuring equipment integrity in high-demand power generation and petrochemical environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-068 (9905-068)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombines redundant speed acquisition with robust industrial communication interfaces.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWoodward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e9905-068 (Revision N)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProTech-GII Overspeed Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Modular Redundant (TMR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTrip Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnergize-to-Trip (ETT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoting Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-out-of-3 (2oo3) Hardware Voting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Redundant supply support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSpeed Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Independent Magnetic Pickups (MPU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 12 ms (Total hardware trip response)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Form-A \/ Form-C Safety Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU \/ Modbus TCP via RS-485 or Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous internal health monitoring \u0026amp; event logging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible with Passive, Active, and Hall-effect sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52519430127800,"sku":"9905-068","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/126._a3e2df0c-2c62-4b6e-a398-45b29a4468dd.jpg?v=1769998060","url":"https:\/\/www.globalpetroparts.com\/products\/woodward-9905-068-module-24vdc-tmr-overspeed-controller","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}