{"product_id":"yokogawa-aai141-s00-centum-vp-16-channel-analog-input-module","title":"Yokogawa AAI141-S00 CENTUM VP 16-Channel Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI141-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog data acquisition interface for the CENTUM VP distributed control system. This module captures 16 channels of standard industrial signals, such as 4-20 mA current loops or 1-5 VDC voltage inputs, to provide the central controller with precise process telemetry. By utilizing a non-isolated architecture between channels, the AAI141-S00 offers a cost-effective solution for high-point-count monitoring where field instruments share a common ground reference. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring peak signal processing performance for your automation network.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe AAI141 series utilizes specific suffix codes to define its functional hardware tier:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAAI141\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 16-Channel Analog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard type hardware for general industrial use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 0 (Standard internal logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type hardware configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AAI141-S00 provides fast, deterministic signal conversion within a compact form factor.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 (Non-isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA or 1 to 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSampling Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 samples per second (10 ms update period)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10°C to +55°C (14°F to +131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 cm x 13 cm x 11 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with CENTUM VP\/CS 3000 I\/O nests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AAI141-S00 solves specific integration and space challenges in modern control rooms:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Loop Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 100 Hz sampling rate ensures the DCS captures rapid process transients. This deterministic performance supports fast-acting control strategies, such as flow regulation and pressure stabilization, where data latency directly affects valve positioning accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximized Cabinet Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 4cm profile allows engineers to pack 16 points into a single module slot. This high-density design significantly reduces the number of I\/O nests required in large-scale plants, lowering total cabinet hardware costs and reducing the footprint of the control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Common-Ground Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn applications where field sensors utilize a shared power source or common return, the non-isolated design of the AAI141-S00 simplifies the wiring schematic. It eliminates the overhead and cost associated with per-channel galvanic isolation when it is not technically required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wide operating range (-10°C to +55°C) permits installation in various cabinet environments, including those without active refrigeration. The module maintains signal accuracy even during ambient temperature fluctuations common in localized field enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main difference between the AAI141-S00 and the AAI143-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAI141-S00 utilizes a non-isolated architecture, meaning the 16 input channels share a common electrical reference. The AAI143-S00 provides full channel-to-channel isolation. Choose the AAI141-S00 for cost-sensitive projects where field instruments already share a common ground.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the AAI141-S00 with both current and voltage signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While typically configured for 4-20 mA current loops, the module hardware accepts 1-5 VDC inputs. Always verify your terminal board configuration and system software settings to match the specific signal type of your field transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the recommended mounting conditions for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstall the AAI141-S00 in a standard Yokogawa I\/O nest. Ensure the cabinet maintains adequate natural convection or forced-air cooling to keep the module within its -10°C to +55°C operating window, especially in high-density rack configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAI141-S00 supports online replacement (hot-swapping) within the CENTUM VP environment, provided the system configuration permits it. This allows maintenance teams to replace the module without shutting down the entire I\/O segment, minimizing process interruptions.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53296853811384,"sku":"AAI141-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AAI141-S00.jpg?v=1776153822","url":"https:\/\/www.globalpetroparts.com\/products\/yokogawa-aai141-s00-centum-vp-16-channel-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}