{"product_id":"yokogawa-aai143-h00-analog-input-module-centum-vp","title":"Yokogawa AAI143-H00 Analog Input Module | CENTUM VP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI143-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog input interface for the CENTUM VP distributed control system. This module processes 16 channels of 4 to 20 mA signals from field transmitters, providing the essential data link between field instrumentation and the control logic. By integrating individual channel isolation, the AAI143-H00 prevents ground loops and maintains signal purity in electrically noisy industrial environments. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compliance with factory specifications.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAAI143\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Module (4 to 20 mA, 16-channel, Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports digital communication via HART protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlaceholder\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type module configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 channels, fully isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHART protocol superimposed on the analog signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 Ω (during power-on).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC between input and system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% of span.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Update Period:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa CENTUM VP \/ CS 3000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced HART Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module enables bi-directional communication with HART-compatible field devices. This allows engineers to perform remote configuration, retrieve diagnostic data, and monitor secondary variables without interrupting the primary 4-20 mA control loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust galvanic isolation protects each of the 16 channels. This design prevents localized electrical faults or surge voltages on one field loop from affecting adjacent channels or the backplane electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Cabinet Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy packing 16 isolated channels into a single slot, the AAI143-H00 reduces the number of I\/O nodes required. This compact architecture lowers total hardware costs and saves valuable space in control room cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResilience Against EMI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware design incorporates high-frequency noise filters. These components suppress electromagnetic interference (EMI) commonly found near variable frequency drives (VFDs) and heavy switchgear, ensuring stable process data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the AAI143-H00 replace a non-HART AAI143 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, you can install the AAI143-H00 as a replacement. It maintains full 4-20 mA analog compatibility while adding the capability to pass HART data to the maintenance station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module supply power to the field transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAI143-H00 supports 2-wire transmitter configurations by providing loop power. It also accepts signals from 4-wire transmitters that utilize an external power source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the module is genuine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe deliver all AAI143-H00 units in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition with original Yokogawa factory seals, serial numbers, and quality inspection certificates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal boards work with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module typically interfaces with the Pressure Clamp Terminal Block (ATA4S\/ATA4D) or the MIL Connector Cable for connection to various Yokogawa marshaling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53438948278456,"sku":"AAI143-H00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AAI143-H50_24ceb597-8de6-42d0-8732-a1aba39ae35a.png?v=1778053352","url":"https:\/\/www.globalpetroparts.com\/products\/yokogawa-aai143-h00-analog-input-module-centum-vp","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}