{"product_id":"yokogawa-att4s-00-centum-vp-terminal-block-adapter","title":"Yokogawa ATT4S-00 CENTUM VP Terminal Block Adapter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ATT4S-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized KS cable interface adapter for the CENTUM VP distributed control system. It provides a standardized connection point to bridge I\/O modules with field terminal boards, specifically designed to handle 16-point analog signals. This adapter ensures a high-integrity physical link, allowing for rapid deployment and organized cable management within marshaling cabinets. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, guaranteed to meet Yokogawa’s strict factory performance standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eATT4S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS Cable Interface Adapter (Terminal side)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog I\/O (compatible with 4-20 mA loops).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-point interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKS Cable Interface (connects to KS1\/KS2 cables).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect interface for AEA4D and related terminal boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa CENTUM VP, CS 3000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20 to 70°C (Storage), 0 to 50°C (Operating).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10% to 90% RH (Non-condensing).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Point-to-Point Wiring Errors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ATT4S-00 consolidates 16 individual analog signals into a single KS cable header. This architecture removes the risk of cross-wiring that often occurs during manual terminal-to-terminal installation, ensuring the right signal reaches the right I\/O channel every time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerate Commissioning Timelines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the \"plug-and-play\" KS cable interface, engineers significantly reduce the time required for loop checks and cabinet assembly. The adapter allows for the simultaneous connection of 16 channels in seconds, rather than hours of manual stripping and lugging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximize Cabinet Space:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact design of the ATT4S-00 optimizes space within marshaling panels. It allows for high-density I\/O configurations, enabling more control loops per square meter of floor space—a critical factor in modernizing existing control rooms with limited footprints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Connection Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe adapter features a secure locking mechanism for KS cables, preventing signal loss due to vibration or accidental mechanical tension. This robust physical connection ensures continuous process uptime in heavy industrial environments like refineries and power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O modules are compatible with the ATT4S-00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ATT4S-00 works seamlessly with 16-channel analog modules such as the AAI141, AAI143, and AAI543 when they are configured for KS cable interfacing rather than direct pressure clamp connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this adapter suitable for redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When used with a redundant terminal board (like the AEA4D), the ATT4S-00 facilitates the connection required to maintain dual-path signal integrity for mission-critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this differ from the ATK4A-00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both are KS adapters, the ATT4S series typically refers to specific terminal-side configurations. Always verify your specific terminal board model (AEA4D, etc.) to ensure the mounting holes and pin-outs align correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the condition of the unit upon delivery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee the unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. Each ATT4S-00 arrives in its original Yokogawa factory box, with original labels and protective packaging intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53438958305464,"sku":"ATT4S-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/ATT4S-00.png?v=1778055081","url":"https:\/\/www.globalpetroparts.com\/products\/yokogawa-att4s-00-centum-vp-terminal-block-adapter","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}