{"product_id":"yokogawa-f3cu04-0s-4-loop-temperature-control-pid-module","title":"Yokogawa F3CU04-0S 4-Loop Temperature Control \u0026 PID Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3CU04-0S\u003c\/strong\u003e is a \u003cstrong\u003e4-loop temperature control and PID module\u003c\/strong\u003e for the FA-M3 series, an enhanced version of the F3CU04 temperature control family. It supports \u003cstrong\u003ethermocouple, RTD, and analog inputs\u003c\/strong\u003e with \u003cstrong\u003eON\/OFF, PID auto\/manual tuning, and ramp\/soak programming\u003c\/strong\u003e. With 8 configurable analog inputs, 4 analog outputs, 16 digital inputs, and 8 digital relay outputs, it provides comprehensive multi-zone temperature management in a single integrated module.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Loops:\u003c\/strong\u003e 4 independent PID loops\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e Thermocouples, RTDs, Analog Inputs (up to 8 configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e Up to 4 configurable outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e 16 points for control\/monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e 8 relay outputs for alarms and control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Functions:\u003c\/strong\u003e ON\/OFF, PID with auto\/manual tuning, ramp\/soak programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling Period:\u003c\/strong\u003e 250 ms per loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS-485, Ethernet, USB ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 460 mA at 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Outputs:\u003c\/strong\u003e 4 points per loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Delay Timer:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Occupies 2 slots, horizontal orientation only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eCompatible with all FA-M3 base modules (occupies 2 slots). Ideal for \u003cstrong\u003emulti-zone furnace control, plastic injection molding, semiconductor wafer processing, pharmaceutical batch reactors, and food\/beverage pasteurization\u003c\/strong\u003e requiring precise ramp\/soak temperature profiles.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between F3CU04-0S and F3CU04-1S?\u003c\/strong\u003e A: F3CU04-0S is the enhanced\/replacement model with additional communication ports (RS-485\/Ethernet\/USB), more I\/O points, and ramp\/soak programming capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it support remote monitoring?\u003c\/strong\u003e A: Yes, built-in Ethernet and RS-485 enable remote monitoring and integration with SCADA systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I program ramp\/soak profiles?\u003c\/strong\u003e A: Yes, F3CU04-0S supports ramp\/soak programming for each loop, ideal for heat treatment applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warm-up time?\u003c\/strong\u003e A: Minimum 30 minutes warm-up is recommended for optimal accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the FA-M3 system.\u003c\/li\u003e\n\u003cli\u003eReserve 2 consecutive horizontal slots in the base module.\u003c\/li\u003e\n\u003cli\u003eInstall F3CU04-0S in horizontal orientation only.\u003c\/li\u003e\n\u003cli\u003eConnect temperature sensors, control outputs, and digital I\/O to terminal blocks.\u003c\/li\u003e\n\u003cli\u003eConfigure network settings if using Ethernet\/RS-485 remote communication.\u003c\/li\u003e\n\u003cli\u003eProgram PID parameters, alarm setpoints, and ramp\/soak profiles via WideField3.\u003c\/li\u003e\n\u003cli\u003eRestore power and allow 30 minutes warm-up before critical operations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose F3CU04-0S for \u003cstrong\u003eadvanced multi-loop temperature control\u003c\/strong\u003e with ramp\/soak and network connectivity.\u003c\/li\u003e\n\u003cli\u003eFor basic 4-loop PID without network features, F3CU04-1S may be sufficient.\u003c\/li\u003e\n\u003cli\u003eEnsure ambient temperature change rate does not exceed 10°C\/hour for accuracy.\u003c\/li\u003e\n\u003cli\u003eUse the digital inputs for interlock\/safety signals and digital outputs for alarm annunciation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53930267705528,"sku":"F3CU04-0S","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F3CU04-0S_2.png?v=1786950535","url":"https:\/\/www.globalpetroparts.com\/products\/yokogawa-f3cu04-0s-4-loop-temperature-control-pid-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}