{"product_id":"yokogawa-f3xc08-0c-no-voltage-contact-input-module","title":"Yokogawa F3XC08-0C No Voltage Contact Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3XC08-0C\u003c\/strong\u003e is an \u003cstrong\u003e8-channel no-voltage contact input module\u003c\/strong\u003e for the FA-M3 series. It accepts \u003cstrong\u003edry contact inputs\u003c\/strong\u003e with \u003cstrong\u003e8 independent commons\u003c\/strong\u003e, making it ideal for monitoring relay contacts, limit switches, and pushbutton states. Transformer isolation provides excellent noise immunity, while selectable response times (2.0 ms or 17 ms) allow optimization for either high-speed or debounced applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e No-voltage contacts (dry contacts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 8 points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon System:\u003c\/strong\u003e 8 independent inputs (separate commons)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Method:\u003c\/strong\u003e Transformer isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e 500V AC for 1 minute (external terminals to internal circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Open Circuit Voltage:\u003c\/strong\u003e 5 to 7 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Closed Circuit Current:\u003c\/strong\u003e 1 to 3 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Resistance:\u003c\/strong\u003e 200 Ω max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Resistance:\u003c\/strong\u003e 100 kΩ min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 2.0 ms max or 17 ms (selectable per input)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 75 mA at 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 170 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e 18-point detachable terminal block (M3.5 screws)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eInstalls in any FA-M3 I\/O slot. Perfect for \u003cstrong\u003elimit switch monitoring, relay status feedback, pushbutton panels, safety interlock systems, and dry-contact sensor applications\u003c\/strong\u003e where isolated, no-voltage inputs are required.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I apply external voltage to the inputs?\u003c\/strong\u003e A: No, do not apply any external voltage to F3XC08-0N input terminals. Use only dry contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum contact rating required?\u003c\/strong\u003e A: External contacts must be able to make and break 5-7V open-circuit voltage and 1-3 mA closed-circuit current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can each input have a different response time?\u003c\/strong\u003e A: Yes, response time (2 ms or 17 ms) is selectable for each individual input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it support interrupt inputs?\u003c\/strong\u003e A: Yes, interrupt function is selectable for each input for time-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the FA-M3 system.\u003c\/li\u003e\n\u003cli\u003eInsert F3XC08-0C into any available I\/O slot.\u003c\/li\u003e\n\u003cli\u003eConnect dry contact switches to the 18-point terminal block.\u003c\/li\u003e\n\u003cli\u003eSet response time switches per input as required (2 ms for fast, 17 ms for debounce).\u003c\/li\u003e\n\u003cli\u003eRestore power and verify input LEDs indicate correct on\/off status.\u003c\/li\u003e\n\u003cli\u003eTest each channel with a known good contact to ensure proper operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse F3XC08-0C for \u003cstrong\u003edry contact applications\u003c\/strong\u003e where external voltage must not be applied.\u003c\/li\u003e\n\u003cli\u003eFor DC voltage inputs (e.g., 24V DC sensors), use F3XD16-3F or F3XD32-3F instead.\u003c\/li\u003e\n\u003cli\u003eThe 8 independent commons allow flexible wiring of devices from different power domains.\u003c\/li\u003e\n\u003cli\u003eSelect 17 ms response time for mechanical switches to eliminate contact bounce effects.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53930246144184,"sku":"F3XC08-0C","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F3XC08-0C.png?v=1786952328","url":"https:\/\/www.globalpetroparts.com\/products\/yokogawa-f3xc08-0c-no-voltage-contact-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}