{"product_id":"yokogawa-fca4-b-centum-vp-pressure-interface-module","title":"Yokogawa FCA4*B CENTUM VP Pressure Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa FCA4*B\u003c\/strong\u003e is an \u003cstrong\u003eautomation interface module\u003c\/strong\u003e designed for pressure and differential pressure (DP) measurement applications within Yokogawa's \u003cstrong\u003eCENTUM VP\u003c\/strong\u003e and \u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e Distributed Control Systems (DCS). It integrates control logic, signal routing, and communication between field pressure transmitters and the control network, enabling centralized monitoring of pressure variables in real time.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Yokogawa CENTUM VP \/ CS 3000 DCS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e Pressure and Differential Pressure (DP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Input:\u003c\/strong\u003e Two pressure sensors (analog or HART)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.075% of span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 4-20 mA, mV, thermocouple, RTD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e FOUNDATION Fieldbus, PROFIBUS DP, HART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 10 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -10°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating:\u003c\/strong\u003e IP20 (panel mount)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Rack-mounted in DCS card nest\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-sensor input capability supports redundant pressure measurement\u003c\/li\u003e\n\u003cli\u003eMulti-protocol communication enables integration with various fieldbus networks\u003c\/li\u003e\n\u003cli\u003eHigh accuracy of ±0.075% ensures precise process control\u003c\/li\u003e\n\u003cli\u003eCompact rack-mount design fits standard Yokogawa DCS card nests\u003c\/li\u003e\n\u003cli\u003eRobust industrial-grade housing withstands harsh process environments\u003c\/li\u003e\n\u003cli\u003eLED status indicators provide at-a-glance module health diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas pipeline pressure monitoring\u003c\/li\u003e\n\u003cli\u003eChemical reactor differential pressure measurement\u003c\/li\u003e\n\u003cli\u003ePower generation boiler and turbine pressure control\u003c\/li\u003e\n\u003cli\u003ePharmaceutical process vessel pressure tracking\u003c\/li\u003e\n\u003cli\u003eWater treatment plant pump discharge pressure monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the suffix *B indicate on the FCA4 module?\u003c\/strong\u003e\u003cbr\u003eA: The suffix letter denotes the hardware revision level. FCA4*B indicates Revision B. Earlier revisions include FCA4*A. Verify compatibility with your specific CENTUM system version before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which DCS platforms are compatible with FCA4*B?\u003c\/strong\u003e\u003cbr\u003eA: The module is designed for Yokogawa CENTUM VP and CENTUM CS 3000 series Distributed Control Systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What sensor types can connect to this module?\u003c\/strong\u003e\u003cbr\u003eA: The module accepts inputs from pressure transmitters outputting 4-20 mA, mV signals, or HART-enabled smart transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module isolated from the field side?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module provides galvanic isolation between field sensor inputs and the system backplane to protect against ground loops and electrical noise.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the DCS rack before installing the module\u003c\/li\u003e\n\u003cli\u003eAlign the FCA4*B module with the card nest guide rails\u003c\/li\u003e\n\u003cli\u003eInsert the module firmly until the backplane connectors engage fully\u003c\/li\u003e\n\u003cli\u003eConnect 24 V DC power to the rack power distribution\u003c\/li\u003e\n\u003cli\u003eWire pressure transmitter signals to the module input terminals per the wiring diagram\u003c\/li\u003e\n\u003cli\u003eConfigure the module parameters in the CENTUM VP engineering station\u003c\/li\u003e\n\u003cli\u003eVerify LED indicators display normal run status\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect FCA4*B for pressure\/DP measurement in CENTUM VP\/CS 3000 systems\u003c\/li\u003e\n\u003cli\u003eVerify your DCS software version supports Revision B hardware\u003c\/li\u003e\n\u003cli\u003eFor earlier system versions, confirm compatibility with FCA4*A\u003c\/li\u003e\n\u003cli\u003eOrder compatible pressure transmitters with 4-20 mA or HART output\u003c\/li\u003e\n\u003cli\u003eEnsure the card nest has available slots for module installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":54012356722872,"sku":"FCA4*B","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FCA4Br270_8fa33419-979f-46c9-9faf-87e39acdb0ec.png?v=1788157113","url":"https:\/\/www.globalpetroparts.com\/products\/yokogawa-fca4-b-centum-vp-pressure-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}