Product Overview
The Honeywell 10208/2/1 is a Relay Output Module for the Honeywell FSC (Fail Safe Control) system. It provides 10 channels of relay contact outputs, supporting both resistive and inductive loads up to 70W with a maximum voltage of 36 Vdc, ideal for applications requiring galvanically isolated switching.
Key Specifications
- Model Number: 10208/2/1
- Product Type: Relay Output Module
- Series: Honeywell FSC (Fail Safe Control)
- Output Channels: 10 channels
- Output Type: Relay contacts (passive)
- Maximum Voltage: 36 VDC
- Maximum Switched Power: 70W (resistive or inductive loads)
- Maximum Current: 2 A per channel
- Maximum Switched Power: 100 W / 1000 VA (per channel ratings)
- Contact Material: Gold-flush silver-cadmium oxide
-
Power Supply:
- 5 VDC: 25 mA
- 24 VDC: 120 mA
- Space Requirements: 4 TE, 3 HE (= 4 HP, 3U)
- Weight: 259g (0.57 lbs)
- Approvals: CE, TÜV, UL
Core Features
- 10 passive relay contact outputs for versatile load switching
- Galvanic isolation between channels and system logic
- Supports both resistive and inductive loads
- High-quality contact material for extended electrical life
- Voltage-free contacts allow flexible external circuit design
Applications
- Relay-based safety interlock systems
- Alarm annunciation and signaling
- Motor contactor control
- Valve solenoid control via relay isolation
- Legacy device integration requiring contact outputs
FAQ
Q: Are the relay contacts voltage-free?
A: Yes, the 10208/2/1 provides passive relay contacts (voltage-free), allowing connection to external circuits at different voltage levels.
Q: What is the maximum load per channel?
A: The maximum switched power is 70W with a maximum voltage of 36 Vdc and maximum current of 2A per channel.
Installation Guide
- Power down the FSC rack before installation.
- Insert the module into the designated I/O slot (4 TE, 3 HE).
- Connect relay contacts to field circuits observing load ratings.
- Install suppression devices for inductive loads if required.
- Verify contact operation via FSC diagnostic tools.
Selection Tips
- For 12-channel relay outputs, consider 10208/1/1.
- For solid-state 24Vdc outputs, consider 10201/2/1 or 10206/2/1.
- Ensure load characteristics (resistive/inductive) are within rated specifications.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag