Bently Nevada
330101-00-08-10-02-05 3300 XL 8 mm Proximity Probe | Bently Nevada
Manufacturer: Bently Nevada
Product No.: 330101-00-08-10-02-05
Product Type: Proximity Sensors
Payment:T/T, Western Union
Weight: 550g
Shipping port: Xiamen
Warranty: 12 months
The Bently Nevada 330101-00-08-10-02-05, also cataloged as the 330101-00-08-10-02-05 Proximity Sensor, operates as a dedicated hardware component for non-contact displacement measurement within TSI monitoring platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 330101-00-08-10-02-05 |
| Brand | Bently Nevada |
| Origin | USA |
| Weight | 0.55 kg |
| Dimensions | 8 mm (Tip Diameter) |
| Operating Temp | -51 deg C to +177 deg C |
| Power Consumption | -24 VDC (nominal, via Proximitor) |
| Total System Length | 1.0 metre |
Eddy-Current Probe Scaling and Rotor Dynamics
The 330101-00-08-10-02-05 transducer is engineered for precise shaft displacement monitoring. It requires a calibrated scaling factor of 7.87 V/mm (200 mV/mil). During site installation, gap voltage validation against the -10 VDC target midpoint is mandatory to ensure linear operation. Deviations from this voltage indicate improper gap positioning, which compromises the accuracy of rotor dynamics data, including shaft centerline behavior and vibration amplitude. To maintain signal integrity, cross-talk suppression must be observed by ensuring adequate physical separation between adjacent probes during multi-channel installation.
Frequently Asked Questions
Q: Is it permissible to field-shorten the integral cable?
A: No. The 330101 system is a factory-calibrated unit consisting of the probe, integral cable, and Proximitor sensor. Field-modifying the cable length alters the electrical impedance, leading to significant measurement inaccuracies.
Q: How is the probe protected against high-pressure fluids?
A: The probe features a Viton O-ring seal at the tip-to-case junction to manage differential pressure. Probes are not pressure-tested prior to shipment; verify sealing integrity per machine-specific requirements if the installation involves high-pressure lubrication or process fluids.
Field Installation Guidelines
- Mounting: Secure the probe in a rigid, vibration-resistant bracket. Ensure the probe tip is installed perpendicular to the target surface to prevent measurement skew.
- Grounding: The probe case is electrically conductive; verify the installation bracket is properly bonded to the machinery casing to maintain immunity to electromagnetic interference (EMI).
- Connector Integrity: Ensure the ClickLoc miniature coaxial connectors are clean and fully seated to prevent intermittent signals. Use high-purity electrical contact cleaner if debris is present.
- Cable Routing: Route coaxial cables through dedicated grounded conduits, maintaining separation from high-voltage AC lines to prevent induced noise on the displacement signal.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag