ABB
ABB D2D146-AA02-22 AC Centrifugal Fan
Manufacturer: ABB
Product No.: D2D146-AA02-22
Product Type: Industrial Cooling Fan
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 4750g
Shipping port: Xiamen
Warranty: 12 months
Description
The D2D146-AA02-22 is a robust AC centrifugal fan manufactured by ABB, designed for high-performance cooling in industrial environments. This unit features a forward-curved, dual-intake design integrated into a durable housing with flange mounting, making it ideal for forced cooling of high-power converters, such as the ABB ACS800 drive series.
Features
- Forward-curved dual-intake centrifugal impeller for efficient airflow.
- Three-phase AC operation (230 VAC) with direction control via phase reversal.
- Integrated thermal overload protection (TOP) for motor safety.
- Compact, flange-mounted construction suitable for cabinet integration.
- Six-pin Molex connector (46992-0610) with PFA insulated wiring.
- High airflow capacity up to 1,600 m³/h at 50 Hz.
Applications
- Forced cooling for high-power industrial converters and drives.
- Control cabinet heat management to prevent thermal throttling.
- Industrial ventilation and air handling units (AHUs).
- Marine automation and power distribution panels.
Technical Specifications
| Model | D2D146-AA02-22 |
| Manufacturer | ABB |
| Nominal Voltage | 230 VAC (3-Phase) |
| Frequency | 50/60 Hz |
| Power Consumption | 290 W (at 50 Hz) |
| Current Draw | 0.81 A (at 50 Hz) |
| Speed | 2250 min-1 |
| Min. Back Pressure | 275 Pa (50 Hz) / 450 Pa (60 Hz) |
| Operating Temp | -25 degC to +60 degC |
| Weight | 4.75 kg |
Connections
- L1 (U1), L2 (V1), L3 (W1): Three-phase power input.
- PE: Protective Earth connection (Class I protection).
- TOP: Thermal Overload Protection lead.
- Connector: 6-pin Molex (Part 46992-0610) using 39-00-0059 socket contacts.
Installation Guidelines
- Mounting: Ensure the unit is securely flange-mounted to a rigid surface to minimize vibration.
- Electrical: Connect the protective earth (PE) wire immediately to ensure safety. Wire the motor according to the specific lead terminal markings.
- Operation: Forward-curved impellers can overload if operated in free-air conditions; maintain minimum back pressure (275 Pa at 50 Hz) during operation.
- Direction: Rotation direction can be reversed by swapping any two of the three phases.
- Handling: Always power down the system before inserting or removing the fan connector.
FAQs
What is the D2D146-AA02-22?
The ABB D2D146-AA02-22 is a 3-phase, AC dual-intake centrifugal fan primarily used in cooling and ventilation applications. It operates at 230 VAC and is designed for industrial-grade heat management.
Is this fan single-phase or three-phase?
It is a 3-phase AC centrifugal fan.
What are the main power requirements?
The fan operates on a 3-phase, 230 VAC supply. It draws 0.81 A at 50 Hz (290W) and 0.76 A at 60 Hz (280W).
What are the safe ambient operating temperatures?
The fan is designed to operate reliably within an ambient climate range of -25 degC to +60 degC.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag