ABB TPM810 800 Series Turbine Protection Module

ABB

ABB TPM810 800 Series Turbine Protection Module

10 left
  • Manufacturer: ABB

  • Product No.: TPM810

  • Product Type: Turbine Protection Module

  • Product Origin: Switzerland

  • Payment:T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The ABB TPM810 is the Turbine Protection Module (Application Module) of the ABB 800 Series S+ Turbine protection system. It works in conjunction with the CPM810 Common Processor Module and TBU810 Terminal Base Unit to form the complete TP800 Turbine Protection Module.

Key Specifications

  • Manufacturer: ABB
  • Part Number: TPM810
  • Product Type: 800 Series Turbine Protection Module (Application Module)
  • System: Symphony Plus S+ Turbine / System 800xA / Profibus-capable DCS
  • Function: Field I/O signal conditioning and digitization for turbine protection
  • Assembly: Plugs into TBU810 Terminal Base Unit together with CPM810
  • Processor: MCF5272 with 16 MB Flash, 25 MHz, 16 MB DRAM (on CPM810)
  • Communication: Profibus DP (via CPM810), Modbus (standalone mode)
  • Power Supply: +24 VDC ±5%
  • Operating Current (no field I/O): 210 mA typical, 300 mA maximum
  • Power Consumption (no field I/O): 6.0 W typical, 7.2 W maximum
  • Speed Inputs: 2 channels (active or passive probes), 0–12,000 Hz, 0.1 Hz accuracy
  • Low Voltage Inputs (LV1-6): Up to 48 V
  • High Voltage Inputs (HV1-2): Up to 150 VAC/VDC
  • Digital Inputs (DI1-2): Up to 220 VAC/VDC (generator breaker, turbine reset)
  • Digital Inputs (DI3-5): 24/48 VDC (miscellaneous trip functions)
  • Analog Inputs (AI1-2): 4–20 mA or 1–5 V (generator MW, intermediate steam pressure)
  • Relay Driver Outputs (DO1-6): 6 independent relay driver outputs, configurable matrix
  • Response Time (Overspeed Trip): < 8 ms
  • Response Time (Trip Anticipation / Load Drop): < 18 ms
  • Safety Certification: IEC/EN 61508 SIL3 certified by TÜV Rheinland (for 2oo3 redundancy, de-energized to trip, periodic overspeed test)
  • Mounting: DIN rail via TBU810 Terminal Base Unit
  • Dimensions: 119 × 106 × 44 mm (L×H×W) — per supplier data
  • Weight: 0.16 kg — per supplier data
  • Operating Temperature: -40°C to +70°C
  • Humidity: 5% to 95% RH (non-condensing)

TP800 System Architecture

The TP800 Turbine Protection Module is comprised of three basic components:

  • CPM810 — Common Processor Module: executes software algorithms and handles Profibus communication
  • TPM810 — Turbine Protection Module (this module): conditions and digitizes field I/O signals
  • TBU810 — Terminal Base Unit: houses CPM810 and TPM810, provides field I/O and Profibus terminations

Optional expansion modules:

  • ROM810v2 — Relay Output Module: 2 relays per module (2-Form C), 3 A @ 150 VDC / 5 A @ 120 VAC
  • ROM830 — 2oo3 Voter Module: electronic voting for redundant trip solenoids
  • PCM810 — Phase Current Module: interfaces to generator CTs for power load unbalance
  • EIM810 — Extended I/O Module: additional hardwired I/O for standalone applications
  • SIM810 — Serial Interface Module: firmware upgrade and standalone configuration

Applications

  • Steam turbine overspeed protection
  • Gas turbine protection systems
  • Hydro turbine safety systems
  • Load drop anticipation (LDA)
  • Power load unbalance (PLU) protection
  • Trip anticipation and acceleration protection
  • Standalone or DCS-integrated turbine protection

FAQ

Q: Can TPM810 operate standalone without a DCS?
A: Yes, when paired with CPM810 in the TBU810, the TP800 can operate in standalone mode using the SIM810 serial interface module for configuration via Turbine Automation Power Tools software. Profibus is not required in standalone mode.

Q: What redundancy schemes does TP800 support?
A: TP800 supports 1oo2, 2oo3 (TMR), and other common protection schemes. For SIL3 certification, a 2oo3 configuration with independent power supplies, de-energized-to-trip logic, and periodic overspeed testing is required.

Q: What is the difference between TPM810 and VPM810?
A: TPM810 is the Turbine Protection Module for TP800. VPM810 is the Valve Positioning Module for VP800. Both use the same CPM810 processor and TBU810 base but have different analog I/O circuitry for their respective functions.

Q: Is TPM810 compatible with non-ABB DCS systems?
A: Yes, the TP800 system can integrate with any Profibus DP-capable DCS platform via the onboard Profibus interface, or operate completely standalone with hardwired I/O.

Installation Guide

  1. Mount the TBU810 Terminal Base Unit on standard 35 mm DIN rail.
  2. Install the CPM810 Common Processor Module into the left slot of the TBU810.
  3. Install the TPM810 Turbine Protection Module into the right slot of the TBU810.
  4. Connect +24 VDC power supply to the TBU810 power terminals.
  5. Wire speed probe inputs (active or passive) to the designated speed input terminals.
  6. Wire digital inputs (generator breaker, turbine reset, trip functions) per the application wiring diagram.
  7. Wire analog inputs (generator MW, steam pressure) if power load unbalance or trip anticipation is enabled.
  8. Connect Profibus DP cable to the TBU810 Profibus port for DCS integration (optional for standalone).
  9. Attach ROM810v2 Relay Output Modules as needed for trip solenoid driving.
  10. Configure protection parameters via Profibus (DCS mode) or SIM810 serial interface (standalone mode).
  11. Perform overspeed test to verify proper operation of protection functions.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.