Allen-Bradley
Allen-Bradley 1756-OB16IF ControlLogix Fast Isolated DC Output Module
Manufacturer: Allen-Bradley
Product No.: 1756-OB16IF
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
The 1756-OB16IF is a high-speed, digitally-isolated DC output module designed for the Allen-Bradley ControlLogix 1756 chassis platform. This module provides 16 independent sourcing output channels, enabling precise control for demanding industrial applications such as high-speed sorting, indexing, and synchronized motion control. With sub-millisecond response times and per-point isolation, it effectively manages complex electrical environments while protecting backplane components from field-side surges.
Features
- 16 individually isolated digital DC sourcing output channels.
- Fast execution speed with response transitions under 25 microseconds.
- Per-point electronic fusing for enhanced circuit protection and diagnostic feedback.
- Supports CIP Sync protocol for high-precision network synchronization.
- Hot-swappable design allows for module replacement without interrupting system power.
- Front-panel LED indicators for real-time channel status and module health monitoring.
Applications
This module is engineered for high-performance automation tasks requiring rapid switching and electrical isolation, including:
- High-speed product sorting and packaging lines.
- Automated assembly and indexing machinery.
- Synchronized cutting and motion-critical industrial processes.
- Systems requiring mixed-voltage DC power sources on a single I/O card.
Technical Specifications
| Model | 1756-OB16IF |
| Outputs | 16 Points (Individually Isolated) |
| Voltage Range | 10 to 30 VDC |
| Response Time | < 25 microseconds |
| Output Current (Per Point) | 2 A @ 30 degC, 1 A @ 60 degC |
| Output Current (Per Module) | 8 A @ 30 degC, 4 A @ 60 degC |
| Backplane Power | 1.7 Watts |
| Isolation Voltage | 250 V (Continuous) |
| Compatible RTBs | 1756-TBCH, 1756-TBS6H |
| Operating Temperature | 0 to 60 degC |
Installation Guidelines
- Ensure the ControlLogix chassis is powered down before inserting or removing the module.
- Use a compatible Removable Terminal Block (RTB) such as the 1756-TBCH or 1756-TBS6H for field wiring.
- Maintain proper grounding practices for the chassis to ensure electromagnetic compatibility and safety.
- Route signal wiring away from high-voltage power lines and sources of significant electromagnetic interference (EMI).
- Verify that the field power supply is within the 10-30 VDC range before energizing the output loops.
- Ensure adequate ventilation in the cabinet to maintain operating temperatures within the 0 to 60 degC range.
FAQ
Q: Does this module require a specific terminal block?
A: Yes, the 1756-OB16IF requires a 36-pin Removable Terminal Block (RTB). Compatible models include the 1756-TBCH (deep cage clamp) and 1756-TBS6H (spring clamp).
Q: Can I use different voltages on the same module?
A: Yes, because the 16 channels are individually isolated, you can connect independent DC power sources to different points on the same module without common-tie interference.
Q: What is the default state of the outputs during a fault?
A: The module is configured to default to the OFF state during a fault, though this can be programmed to Hold Last State or ON depending on your application requirements.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag