Honeywell 2MLL-C42B 2-Channel RS-422/RS-485 Serial Communication Module
Manufacturer: Honeywell
Product No.: 2MLL-C42B
Product Type: Communication Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell 2MLL-C42B is a 2-channel RS-422/RS-485 serial communication module for the MasterLogic-200 (ML200) PLC system. It enables robust, noise-immune serial data exchange between the ML200 CPU and third-party devices such as variable frequency drives, weigh scales, barcode readers, and legacy instrumentation. Supporting Modbus RTU/ASCII master and slave functions, it serves as a versatile fieldbus gateway for mixed-vendor automation architectures.
Key Specifications
- Product Type: Serial Communication Module (RS-422/RS-485)
- Series: MasterLogic-200 / ML200
- Channels: 2
- Interface: RS-422 / RS-485 (software selectable)
- Isolation: 1500V between channels and communication lines
- Supported Protocols: Modbus RTU, Modbus ASCII, dedicated protocol, user-defined protocol
- Baud Rate: 300 bps to 115,200 bps
- Data Format: 7/8 data bits, 1/2 stop bits, odd/even/none parity
- Transmission Distance: Up to 1,200 meters (RS-422 at 9,600 bps)
- Connection: 9-pin D-sub connector (per channel)
- Current Consumption: 40 mA (from 5V internal bus)
- External Power: DC 24V (20.4–28.8V)
- Dimensions (W x H x D): 27.4 mm x 90 mm x 70 mm
- Weight: Approx. 90 g
- Operating Temperature: 0°C to +55°C
Features & Benefits
- Dual isolated channels — run two independent serial networks from one module, reducing hardware count by 50%
- RS-422/RS-485 selectable — software-configurable interface type eliminates the need for separate modules
- 1500V galvanic isolation — protects the CPU from ground potential differences and electrical noise on long cable runs
- Modbus RTU/ASCII native support — built-in master and slave functions eliminate custom protocol programming
- Long-distance capability — 1,200 meter range enables connection to remote field devices without repeaters
Typical Applications
- VFD parameter read/write and status monitoring
- Weigh scale and load cell indicator integration
- Barcode scanner and RFID reader communication
- Legacy PLC and DCS gateway integration
- Remote terminal unit (RTU) communication in SCADA systems
- Multi-drop Modbus networks with up to 32 devices per channel
Installation Guide
- Select RS-422 or RS-485 mode — in SoftMaster, configure each channel for point-to-point (RS-422) or multi-drop (RS-485) operation.
- Install in I/O slot — mount the 2MLL-C42B in any available ML200 I/O slot.
- Connect 24V external power — wire DC 24V to the external power terminals for the interface drivers.
- Wire serial network — connect TX+, TX-, RX+, and RX- (RS-422) or A/B (RS-485) using twisted-pair shielded cable. Ground the shield at one end only.
- Configure protocol in SoftMaster — set baud rate, data format, and protocol type (Modbus RTU master/slave or dedicated protocol).
- Test communication — use the SoftMaster monitor function to verify data register exchange with the connected device.
FAQ
Q: What is the difference between 2MLL-C42B and 2MLL-C42A?
A: The 2MLL-C42B is the standard RS-422/RS-485 2-channel module. The 2MLL-C42A is a variant with potentially different firmware or connector orientation. Both support identical electrical specifications and protocols. Verify your system BOM for the exact suffix required.
Q: Can I use this for RS-232C devices?
A: No. For RS-232C applications, use the 2MLL-C22A (2-channel RS-232C) or 2MLL-CH2A (1ch RS-232C + 1ch RS-422) module.
Q: What is the maximum number of devices per RS-485 channel?
A: RS-485 supports up to 32 devices per channel (1 driver + 31 receivers). For networks with >32 devices, use RS-485 repeaters or split into multiple channels.
Q: Does this module support protocol conversion?
A: The 2MLL-C42B supports Modbus RTU/ASCII natively. For protocol conversion (e.g., Modbus to Profibus), use the 2MLL-PMEA (Profibus Master) or 2MLL-PSEA (Profibus Slave) modules.
Selection Tips
- Select 2MLL-C42B for RS-422/RS-485 serial communication with drives, scales, and barcode readers.
- If you need RS-232C instead, choose 2MLL-C22A (2-channel RS-232C).
- For mixed RS-232C and RS-422 on one module, select 2MLL-CH2A.
- Always use twisted-pair shielded cable for RS-422/RS-485 runs >100 meters to prevent electromagnetic interference.
- Verify your termination resistor requirements for RS-485 multi-drop networks to prevent signal reflections.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag