Honeywell 2MLP-DC42 DC Input Power Supply Module 24V 6A

Honeywell

Honeywell 2MLP-DC42 DC Input Power Supply Module 24V 6A

9 left
  • Manufacturer: Honeywell

  • Product No.: 2MLP-DC42

  • Product Type: Power Supply Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The Honeywell 2MLP-DC42 is a DC input power supply module for the MasterLogic-200 (ML200) non-redundant PLC system. It accepts DC 24V input and delivers regulated DC 5V at 6A to power the CPU, I/O modules, and communication modules on the backplane. Designed for battery-backed and solar-powered installations, it provides reliable power conversion with built-in overcurrent, overvoltage, and short-circuit protection.

Key Specifications

  • Product Type: DC Input Power Supply Module
  • Series: MasterLogic-200 / ML200 (Non-Redundant)
  • Input Voltage: DC 24V (19.2–28.8V range)
  • Input Current: Up to 80 A peak (inrush)
  • Output Voltage: DC 5V ±2%
  • Output Current: 6.0 A
  • Efficiency: ≥85% (typical)
  • Ripple Voltage: ≤50 mV peak-to-peak (at full load)
  • Response Time: ≤10 ms
  • Protection: Overcurrent (≥6.6A), Overvoltage (5.5–6.5V), Short-circuit
  • Input Fuse: Built-in, UL standard slow blow (non-changeable)
  • Run Contact: Built-in relay contact for power status indication
  • Allowed Instantaneous Interruption: 10 ms and shorter
  • Dimensions (W x H x D): 15.2 cm x 2.4 cm x 12.6 cm
  • Weight: Approx. 0.5 kg (500 g)
  • Mounting: One-slot install in MasterLogic-200 rack
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -25°C to +70°C

Features & Benefits

  • DC 24V input for battery-backed systems — ideal for UPS-backed control systems, solar-powered remote sites, and marine DC bus architectures
  • 6A high capacity — supports fully loaded 12-slot non-redundant racks with CPU, communication, and high-density I/O modules
  • 10 ms hold-up time — maintains 5V output during brief input interruptions (<10 ms), preventing CPU restarts during utility voltage sags
  • Built-in protections — overcurrent, overvoltage, and short-circuit protection safeguard the power supply and downstream modules from electrical faults
  • Non-changeable internal fuse — UL-rated slow-blow fuse provides fault isolation without user maintenance
  • Run contact output — dry relay contact interfaces with alarm systems or BMS for remote power status monitoring

Typical Applications

  • Battery-backed control systems in power substations
  • Solar-powered remote pump stations and RTUs
  • Marine vessel DC bus control systems
  • Telecom shelter environmental control
  • Emergency generator control panels
  • Any application requiring DC input power for the PLC rack

Installation Guide

  1. Verify DC input source — confirm your site provides stable DC 24V (19.2–28.8V). Verify the battery or DC bus can supply the required current.
  2. Install in power supply slot — mount the 2MLP-DC42 in the dedicated power supply slot of the ML200 main base (2MLB-MxxA).
  3. Connect DC input — wire DC 24V positive and negative to the input terminals. Observe correct polarity.
  4. Connect earth ground — bond the PE terminal to the cabinet earth bus with 2.5 mm² wire.
  5. Wire run contact — connect the built-in relay contact to your alarm system or PLC diagnostic input for remote monitoring.
  6. Verify output — use a precision multimeter to confirm 5.00 V DC ±2% at the backplane power test points.

FAQ

Q: What is the difference between 2MLP-DC42 and 2MLP-ACF2?
A: The 2MLP-DC42 accepts DC 24V input. The 2MLP-ACF2 accepts AC 85–264V input. Both output 5V DC at 6A. Choose DC42 for battery-backed or DC bus applications; choose ACF2 for standard AC mains applications.

Q: What is the difference between 2MLP-DC42 and 2MLR-DC42?
A: The 2MLP-DC42 is for non-redundant ML200 systems. The 2MLR-DC42 is for redundant ML200R systems with active-active load sharing. They are not interchangeable due to different mechanical and electrical interfaces.

Q: Can I use this in a redundant ML200R system?
A: No. The 2MLP-DC42 is designed for non-redundant ML200 bases only. Redundant systems require 2MLR-DC42 (7.5A redundant DC input).

Q: What happens during a power interruption >10 ms?
A: If the DC input is interrupted for more than 10 ms, the 2MLP-DC42 will shut down and the CPU will enter stop mode. Ensure your battery or UPS can maintain 24V during switchover events.

Selection Tips

  • Select 2MLP-DC42 for DC 24V battery-backed or solar-powered non-redundant systems.
  • For AC mains input, choose 2MLP-ACF2 (AC 85–264V) instead.
  • For redundant DC input, upgrade to 2MLR-DC42 (7.5A) in an ML200R system.
  • Verify your battery capacity — the 2MLP-DC42 draws approximately 1.5A at 24V input for a fully loaded rack.
  • Always use fused DC input wiring — size the external fuse at 125% of the maximum input current.