Global Petro Parts Automation
Honeywell 2MLQ-RY2A 16-Point Relay Output Module
Manufacturer: Global Petro Parts Automation
Product No.: 2MLQ-RY2A
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell 2MLQ-RY2A is a 16-point relay output module for the MasterLogic-200 (ML200) PLC system. Each point features an independent Form A (SPST-NO) relay contact rated at 2A per point with a common capacity of 5A per COM terminal. It is the ideal choice for switching AC or DC loads of varying voltages — from 24V DC solenoids to 220V AC contactor coils — within a single module, eliminating the need for external interposing relays in mixed-voltage applications.
Key Specifications
- Product Type: 16-Point Relay Output Module
- Series: MasterLogic-200 / ML200
- Output Points: 16
- Output Type: Relay (SPST-NO)
- Rated Load Voltage: DC 24V / AC 220V (max)
- Rated Load Current: 2A per point (resistive)
- Common Current: 5A per COM terminal
- Minimum Load: DC 5V, 1 mA
- Response Time: ≤ 10 ms (ON→OFF / OFF→ON)
- Mechanical Life: 20,000,000 operations
- Electrical Life: 100,000 operations (rated load)
- Isolation Method: Relay isolation (coil to contact)
- Isolation Voltage: AC 1,500V rms / 1 minute
- External Connection: 40-point connector
- Current Consumption: 70 mA (from 5V internal bus)
- Dimensions (W x H x D): 27.4 mm x 90 mm x 70 mm
- Weight: Approx. 120 g
- Operating Temperature: 0°C to +55°C
Features & Benefits
- Universal AC/DC switching — relay contacts handle both AC and DC loads from 5V to 220V, eliminating the need for separate AC and DC output modules
- 16-point high density — compact 27.4 mm width delivers 16 independent relay outputs, reducing module count and panel footprint
- 5A common capacity — each COM terminal supports up to 5A, enabling grouped load switching for solenoid valve manifolds and contactor banks
- 20 million mechanical operations — long relay life reduces maintenance frequency in high-cycling applications such as packaging and sorting
- 1,500V AC isolation — galvanic separation between PLC logic and field power protects the CPU from voltage transients and ground faults
Typical Applications
- Contactor and motor starter coil control in MCC panels
- Solenoid valve manifold switching in pneumatic systems
- Heater and lighting circuit control in building automation
- Alarm horn and strobe activation in safety systems
- Conveyor diverter gate and stopper cylinder control
- Mixed-voltage systems with both 24V DC and 110/220V AC loads
Installation Guide
- Verify load ratings — confirm each load is ≤2A resistive and the total per COM group is ≤5A.
- Install on de-energized base — align the module and press firmly until the retention clips engage.
- Install surge suppressors for inductive loads — place RC snubbers or flyback diodes across solenoid coils and contactor coils to extend relay contact life.
- Connect 40-pin field cable — use the Honeywell 40-point connector or terminal block adapter (TG7-1H40S) to wire loads.
- Apply field power — connect the appropriate AC or DC supply to the COM terminals and wire loads to the output points.
- Test each point — force each output ON via SoftMaster and verify the load energizes and the output LED illuminates.
FAQ
Q: What is the difference between 2MLQ-RY2A and 2MLQ-RY2B?
A: The 2MLQ-RY2B includes a built-in varistor for surge suppression on each output. The 2MLQ-RY2A requires external suppression. Choose RY2B for inductive load applications (solenoids, contactors) to reduce external component count.
Q: Can I switch motor loads directly?
A: No. The 2A rating is for resistive loads. Motor starting currents exceed this limit. Use the 2MLQ-RY2A to switch a contactor coil, which then controls the motor.
Q: What is the maximum voltage?
A: The relay contacts are rated for AC 250V / DC 30V maximum. Do not exceed these ratings — doing so will damage the relay and void the warranty.
Q: Can I mix AC and DC loads on the same module?
A: Yes. Each output is independent. You can switch DC loads on some points and AC loads on others, provided each point and COM group remains within rated current.
Selection Tips
- Choose 2MLQ-RY2A for general-purpose relay output with mixed AC/DC voltages.
- For inductive loads (solenoids, contactors), upgrade to 2MLQ-RY2B with built-in varistor protection.
- For high-speed switching (>1 Hz), use transistor output modules (2MLQ-TR2A for sink type or 2MLQ-TR2B for source type) instead of relays.
- Always install external fuses on each COM group to protect against short-circuit damage.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.