Skip to product information
Honeywell 2MLR-AC22 Redundant Power Supply Module AC 220V 5.5A

Global Petro Parts Automation

Honeywell 2MLR-AC22 Redundant Power Supply Module AC 220V 5.5A

In stock
  • Manufacturer: Global Petro Parts Automation

  • Product No.: 2MLR-AC22

  • Product Type: Power Supply Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1400g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The Honeywell 2MLR-AC22 is a redundant power supply module for the MasterLogic-200R (ML200R) PLC system. It accepts AC 220V input and delivers regulated DC 5V at 5.5A to power redundant CPU racks, I/O modules, and communication interfaces. With active-active load sharing and hot-swap capability, it ensures continuous power delivery for critical control applications in power generation, oil & gas, and chemical processing where unplanned shutdowns are not acceptable.

Key Specifications

  • Product Type: Redundant Power Supply Module
  • Series: MasterLogic-200R (Redundant)
  • Input Voltage: AC 220V (200–240V range)
  • Output Voltage: DC 5V (regulated ±2%)
  • Output Current: 5.5A
  • Redundancy Type: Active-Active (parallel sharing)
  • Switchover Time: Zero (seamless failover)
  • Efficiency: >85%
  • Protection: Overvoltage, overcurrent, short-circuit, thermal shutdown
  • Run Contact: SPDT relay contact (250V AC / 2A) for status indication
  • Hot-Swappable: Yes
  • Dimensions (W x H x D): 122 mm x 35 mm x 100 mm
  • Weight: Approx. 0.45 kg
  • Operating Temperature: 0°C to +55°C
  • Certifications: CE, RoHS

Features & Benefits

  • 220V AC input for international sites — designed for European, Asian, and Australian mains voltage standards, eliminating the need for step-down transformers
  • Active-active redundancy — dual 2MLR-AC22 modules share the load; failure of one supply results in instantaneous, bumpless transfer to the surviving unit
  • Hot-swap maintenance — defective power supplies can be extracted and replaced while the process continues to run, maximizing system availability
  • Built-in run contact — dry contact output interfaces with BMS, SCADA, or annunciator panels for immediate power fault notification
  • 5.5A capacity — supports 6-slot redundant racks with CPU, communication, and moderate I/O loading

Typical Applications

  • European chemical plant DCS backup control
  • Asian automotive assembly line safety systems
  • Australian mining conveyor control and protection
  • Offshore platform topside process control
  • Pharmaceutical freeze-dryer and sterilizer control
  • Any AC 220V site requiring SIL 2 or high-availability architecture

Installation Guide

  1. Confirm mains voltage — verify your site provides AC 220V (200–240V). For AC 110V sites, use 2MLR-AC12 or 2MLR-AC13 instead.
  2. Install in redundant power slots — mount two 2MLR-AC22 modules in the dedicated power supply slots of the ML200R main base.
  3. Wire independent feeds — connect each power supply to a separate AC circuit breaker and distribution panel to achieve true power source diversity.
  4. Connect earth ground — bond the PE terminal to the cabinet earth bus with 2.5 mm² wire.
  5. Wire run contacts — connect the SPDT relay contacts to your alarm system or PLC diagnostic input for remote monitoring.
  6. Test failover — energize both supplies, confirm load sharing, then remove one supply and verify the second maintains 5V output without CPU fault.

FAQ

Q: What is the difference between 2MLR-AC22 and 2MLR-AC23?
A: The 2MLR-AC22 provides 5.5A output. The 2MLR-AC23 provides 8.5A output. Both accept AC 220V input. Choose AC22 for 2-slot and 6-slot racks; choose AC23 for fully loaded 12-slot racks.

Q: Can I mix AC22 and AC23 in the same rack?
A: No. Honeywell recommends using identical power supply models in redundant pairs to ensure equal load sharing and prevent circulating currents.

Q: Is this compatible with non-redundant ML200 bases?
A: No. The 2MLR-AC22 is mechanically and electrically designed for ML200R redundant bases only (2MLR-M02P, 2MLR-M06P).

Q: What is the efficiency and heat dissipation?
A: At >85% efficiency, a fully loaded 2MLR-AC22 dissipates approximately 15–20W as heat. Ensure 50 mm clearance above and below the module for convective cooling.

Selection Tips

  • Select 2MLR-AC22 for AC 220V sites with 2-slot or 6-slot redundant racks.
  • For 12-slot fully loaded racks, upgrade to 2MLR-AC23 (8.5A) to ensure adequate power margin.
  • For AC 110V sites, choose 2MLR-AC12 (5.5A) or 2MLR-AC13 (8.5A).
  • Always install two identical power supplies per rack — never run redundant systems with a single supply.
  • Calculate your total 5V bus load (CPU + I/O + communication modules) before ordering; a 6-slot rack with high-density I/O typically requires 5.5A, while 12-slot racks need 8.5A.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.

You may also like