Honeywell
Honeywell 900RSM-0101 Redundant Switch Module (RSM)
Manufacturer: Honeywell
Product No.: 900RSM-0101
Product Type: Redundant Switch Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell 900RSM-0101 is a Redundant Switch Module (RSM) designed for the ControlEdge HC900 redundant controller rack. It manages seamless failover between the Lead and Reserve CPUs, providing real-time status indication, manual switchover capability, and key-switch mode control. The 900RSM-0101 ensures high availability in critical process control and safety applications by eliminating single points of failure in the controller architecture. It supports Insertion/Removal Under Power (IRUP) without inducing a controller failover.
Key Features
- Redundancy management between Lead and Reserve CPUs
- Lead/Reserve LED indicators for instant CPU status visibility
- Manual failover key switch — force switchover from Lead to Reserve
- Mode selection key switch: RUN, PROGRAM, RUN/PROG
- Hot-swappable (IRUP) — may be replaced under power without inducing failover
- C70R CPUs remain in last used mode during RSM replacement
- One RSM required per redundant controller rack
- Class 1, Division 2, Groups A,B,C,D, T6 hazardous location rating
Technical Specifications
- Model: 900RSM-0101
- Product Type: Redundant Switch Module (RSM)
- Series: ControlEdge HC900
- Function: Redundancy management, manual failover, mode control
- CPU Compatibility: C70R, C75 redundant CPUs
- Indicators: Lead/Reserve status LEDs
- Key Switches: Mode (RUN / PROGRAM / RUN/PROG) + Manual failover
- Hot-Swap Support: IRUP — insertion/removal under power supported
- Failover Behavior: Replacement does not induce controller failover
- Rack Requirement: One per redundant controller rack
- Operating Temperature: 0°C to +60°C
- Storage Temperature: −25°C to +70°C
- Humidity: 5% to 95% RH (non-condensing)
- Weight: Approx. 0.5 kg (500 g)
- Dimensions: Standard HC900 module form factor
- Hazardous Location: Class 1, Div 2, Groups A,B,C,D, T6
- Certifications: CE, UL, CSA, TÜV
Typical Applications
- Redundant controller architectures for high-availability process control
- Safety instrumented systems (SIS) requiring no single point of failure
- Critical batch and continuous process automation
- Oil & gas production and refining
- Power generation and turbine control
FAQ
Q: What does the 900RSM-0101 do?
A: It manages redundancy between the Lead and Reserve CPUs, provides status indicators, and allows manual failover via a key switch.
Q: Can I replace the RSM while the system is running?
A: Yes. The 900RSM-0101 supports IRUP (Insertion/Removal Under Power). Removing or replacing it does not induce a controller failover, and the C70R CPUs remain in their last used mode.
Q: How many RSMs are needed per system?
A: One RSM is installed in each redundant controller rack.
Q: What modes can be set with the key switch?
A: RUN, PROGRAM, and RUN/PROG. The switch also allows forcing a manual failover from Lead to Reserve CPU.
Q: Is this module required for non-redundant systems?
A: No. The RSM is only used in redundant controller configurations with dual CPUs.
Installation Guide
- Power Planning: The RSM can be inserted or removed under power, but follow your plant's safety procedures.
- Slot Placement: Install the 900RSM-0101 in the designated RSM slot in the redundant controller rack, typically positioned between the two CPUs.
- Key Switch Setup: Set the mode key switch to the desired operating mode (RUN, PROGRAM, or RUN/PROG) before or during commissioning.
- Failover Test: During commissioning, test manual failover using the key switch to verify Reserve CPU assumes control correctly.
- Status Verification: Confirm Lead/Reserve LEDs indicate the correct active and standby CPUs.
- Replacement Procedure: If replacing the RSM, simply remove the old module and insert the new one. The CPUs will maintain their last mode and control will not transfer.
Selection Tips
- Select the 900RSM-0101 for newer HC900 redundant controller racks (check your rack part number compatibility).
- For legacy redundant racks, verify whether the 900RSM-0001 or 900RSM-0200 is required instead.
- Ensure your CPU firmware supports the RSM revision before installation.
- Always pair with a redundant CPU rack (900RR0-xxxx) and dual redundant CPUs (C70R/C75).
- Plan operator training on the manual failover key switch for emergency procedures.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.