Skip to product information
Honeywell 900RTR-H001 Relay Output Remote Terminal Panel

Honeywell

Honeywell 900RTR-H001 Relay Output Remote Terminal Panel

6 left
  • Manufacturer: Honeywell

  • Product No.: 900RTR-H001

  • Product Type: Terminal Panel

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The Honeywell 900RTR-H001 is a Relay Output Remote Terminal Panel (RTP) designed for the ControlEdge HC900 controller family. It provides isolated termination for relay output modules, maintaining the electrical isolation of each relay channel while enabling convenient field wiring access. With individual fuses per output and selectable power disconnect switches per relay common, the 900RTR-H001 enhances safety and simplifies maintenance for relay-based control applications.

Key Features

  • Relay output termination with maintained isolation per channel
  • Individual fuses for each relay output for overcurrent protection
  • Selective power disable switches per relay common terminal
  • Supports IRUP (Insertion/Removal Under Power) by disconnecting field power
  • DIN rail mounting for flexible cabinet placement
  • Max 24 A total current for all outputs per RTP
  • Compact dimensions: 111.1 × 94.0 × 66.0 mm

Technical Specifications

  • Model: 900RTR-H001
  • Product Type: Relay Output Remote Terminal Panel (RTP)
  • Series: ControlEdge HC900
  • I/O Type: Relay Output
  • Max Total Current: 24 A for all outputs per RTP
  • Protection: Individual fuse per output channel
  • Power Control: Switch-selectable disable per relay common
  • Isolation: Maintains relay module isolation
  • Mounting Type: DIN rail
  • Dimensions (L × W × H): 111.1 × 94.0 × 66.0 mm (4.38" × 3.70" × 2.60")
  • Weight: ~0.5 kg
  • Cable Compatibility: 900RTC-H010, 900RTC-H025, 900RTC-H050 (high voltage)
  • Operating Temperature: 0°C to +60°C
  • Storage Temperature: −40°C to +85°C
  • Certifications: CE

Typical Applications

  • Relay output field termination for motor starters and contactors
  • Valve solenoid control via relay isolation
  • Alarm horn and indicator light driving
  • Heater and fan control circuits
  • Systems requiring IRUP capability on relay modules

FAQ

Q: What is the maximum current the 900RTR-H001 can handle?
A: The panel supports a maximum of 24 A total current across all relay outputs.

Q: Are fuses included?
A: Yes. Each relay output has an individual fuse for overcurrent protection.

Q: Can I disable power to individual relays?
A: Yes. The panel provides switches per relay common terminal to selectively disable field power.

Q: Does it support hot-swapping of relay modules?
A: Yes. By disabling field power via the common switches, you can safely perform IRUP on the connected relay module.

Q: What cables are used to connect to the I/O module?
A: Use high-voltage RTP cables such as 900RTC-H010 (1.0 m), 900RTC-H025 (2.5 m), or 900RTC-H050 (5.0 m).

Installation Guide

  1. DIN Rail Mounting: Install the 900RTR-H001 on a standard 35 mm DIN rail in the control cabinet.
  2. Field Wiring: Connect relay-controlled loads to the output terminals. Ensure wire gauge is adequate for the load current (max 24 A total).
  3. Fuse Verification: Confirm correct fuse ratings are installed for each output channel based on load requirements.
  4. RTP Cable Connection: Connect the high-voltage RTP cable from the panel to the HC900 relay output module.
  5. Common Switch Setup: Configure the common terminal switches according to your relay grouping requirements.
  6. IRUP Procedure: To hot-swap the relay module, first disable the appropriate common switches to remove field power, then replace the module.

Selection Tips

  • Select the 900RTR-H001 for relay output field termination requiring isolation and individual fusing.
  • For digital/analog I/O, use the 900RTS-0001 general-purpose RTP.
  • For analog input termination, use the 900RTA-L001 analog input RTP.
  • Ensure total load current does not exceed 24 A per RTP.
  • Use high-voltage RTP cables (900RTC-Hxxx series) for connection to relay output modules.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.