Skip to product information
Yokogawa AAI141-S00 CENTUM VP 16-Channel Analog Input Module

Yokogawa

Yokogawa AAI141-S00 CENTUM VP 16-Channel Analog Input Module

In stock
  • Manufacturer: Yokogawa

  • Product No.: AAI141-S00

  • Product Type: Analog Input Module

  • Product Origin: JANPAN

  • Payment:T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The Yokogawa AAI141-S00 functions as a high-density analog data acquisition interface for the CENTUM VP distributed control system. This module captures 16 channels of standard industrial signals, such as 4-20 mA current loops or 1-5 VDC voltage inputs, to provide the central controller with precise process telemetry. By utilizing a non-isolated architecture between channels, the AAI141-S00 offers a cost-effective solution for high-point-count monitoring where field instruments share a common ground reference. We supply this unit as 100% Brand New and original, ensuring peak signal processing performance for your automation network.

Part Number Breakdown

The AAI141 series utilizes specific suffix codes to define its functional hardware tier:

Suffix Code Engineering Definition
AAI141 Base Model: 16-Channel Analog Input Module
-S Standard type hardware for general industrial use
0 Always 0 (Standard internal logic)
0 Basic type hardware configuration

Technical Specifications

The AAI141-S00 provides fast, deterministic signal conversion within a compact form factor.

  • Manufacturer: Yokogawa Electric Corporation

  • Number of Channels: 16 (Non-isolated)

  • Input Signal Range: 4 to 20 mA or 1 to 5 VDC

  • Sampling Rate: 100 samples per second (10 ms update period)

  • Operating Temperature: -10°C to +55°C (14°F to +131°F)

  • Dimensions: 4 cm x 13 cm x 11 cm

  • Weight: 0.3 kg

  • System Interface: Compatible with CENTUM VP/CS 3000 I/O nests

  • Condition: 100% Brand New and Original

Engineering Advantages

The AAI141-S00 solves specific integration and space challenges in modern control rooms:

  • High-Speed Loop Monitoring: A 100 Hz sampling rate ensures the DCS captures rapid process transients. This deterministic performance supports fast-acting control strategies, such as flow regulation and pressure stabilization, where data latency directly affects valve positioning accuracy.

  • Maximized Cabinet Density: The slim 4cm profile allows engineers to pack 16 points into a single module slot. This high-density design significantly reduces the number of I/O nests required in large-scale plants, lowering total cabinet hardware costs and reducing the footprint of the control room.

  • Simplified Common-Ground Wiring: In applications where field sensors utilize a shared power source or common return, the non-isolated design of the AAI141-S00 simplifies the wiring schematic. It eliminates the overhead and cost associated with per-channel galvanic isolation when it is not technically required.

  • Industrial Thermal Resilience: The wide operating range (-10°C to +55°C) permits installation in various cabinet environments, including those without active refrigeration. The module maintains signal accuracy even during ambient temperature fluctuations common in localized field enclosures.

FAQs

What is the main difference between the AAI141-S00 and the AAI143-S00?

The AAI141-S00 utilizes a non-isolated architecture, meaning the 16 input channels share a common electrical reference. The AAI143-S00 provides full channel-to-channel isolation. Choose the AAI141-S00 for cost-sensitive projects where field instruments already share a common ground.

Can I use the AAI141-S00 with both current and voltage signals?

Yes. While typically configured for 4-20 mA current loops, the module hardware accepts 1-5 VDC inputs. Always verify your terminal board configuration and system software settings to match the specific signal type of your field transmitters.

What are the recommended mounting conditions for this module?

Install the AAI141-S00 in a standard Yokogawa I/O nest. Ensure the cabinet maintains adequate natural convection or forced-air cooling to keep the module within its -10°C to +55°C operating window, especially in high-density rack configurations.

Does this module support hot-swapping?

The AAI141-S00 supports online replacement (hot-swapping) within the CENTUM VP environment, provided the system configuration permits it. This allows maintenance teams to replace the module without shutting down the entire I/O segment, minimizing process interruptions.