Skip to product information
1746-NT8 SLC 500 Thermocouple/mV Analog Input Module | Allen-Bradley

Allen Bradley

1746-NT8 SLC 500 Thermocouple/mV Analog Input Module | Allen-Bradley

10 left
  • Manufacturer: Allen Bradley

  • Product No.: 1746-NT8

  • Product Type: Analog Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 3180g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The Allen-Bradley 1746-NT8 acts as a high-density temperature sensing interface for the SLC 500 PLC platform. This module provides eight channels for direct connection to thermocouples or millivolt (mV) signals without requiring external signal conditioners. By converting low-level analog signals into digital data using high-precision Sigma-Delta modulation, this module ensures accurate thermal monitoring for kilns, ovens, and chemical processes. We supply this product as 100% Brand New and Original, ensuring optimal calibration and sensor integrity from day one.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Module Type Thermocouple / mV Analog Input
Number of Inputs 8 Isolated Channels
Supported Sensors J, K, T, E, S, R, B, and N Thermocouples
mV Range ±50 mV and ±100 mV
A/D Conversion Sigma-Delta Modulation
Resolution 16-bit Input
Update Time 356 ms to 4.05 s (Filter dependent)
Backplane Current 120 mA @ 5V DC / 70 mA @ 24V DC
Operating Temp 0°C to 60°C (32°F to 140°F)

Engineering Advantages

  • High-Precision Signal Processing: The 16-bit resolution captures minute temperature fluctuations. The Sigma-Delta conversion method filters out industrial electrical noise, providing stable data in high-interference environments.

  • Versatile Sensor Integration: A single 1746-NT8 supports eight different thermocouple types (J, K, T, E, S, R, B, N) and millivolt ranges. This flexibility allows engineers to standardize on one module for varied thermal sensing needs.

  • Smart Diagnostics: The module features Open Circuit Detection. You can configure the system to drive values Upscale, Downscale, or to Zero upon sensor failure. This capability prevents "runaway" heating scenarios and protects downstream equipment.

  • Streamlined Rack Utilization: By packing eight channels into a single SLC slot, the 1746-NT8 reduces the physical footprint of your control system and lowers the overall cost per point for large-scale temperature monitoring.

FAQs

  • Where should I install the 1746-NT8 in the SLC chassis? You can place the 1746-NT8 in any available I/O slot of a 1746 chassis, except for Slot 0, which the CPU always occupies. Ensure your power supply provides sufficient 5V and 24V DC backplane current for all modules.

  • Does the module require cold-junction compensation (CJC)? Yes. The module automatically performs cold-junction compensation. For maximum accuracy, maintain stable ambient temperatures around the terminal block and avoid installing the module near heat-generating components like power supplies or motor starters.

  • How does the update time vary? The update time depends on the number of enabled channels and the selected filter frequency. Disabling unused channels significantly accelerates the data refresh rate for active sensors.

  • What happens if a thermocouple wire breaks? The module detects an open circuit immediately. Depending on your configuration in the SLC 500 programming software, the input data will default to a specific state (Maximum, Minimum, or Zero) to trigger your safety interlocking logic.