Configured for displacement measurement in rotating machinery, the Bently Nevada 330103-00-11-10-02-05 (330103-00-11-10-02-05 Proximity Probe) provides direct physical signal transduction for vibration and position monitoring.

Suffix Breakdown & Model Matrix

Suffix Option Specification
Unthreaded Length 00 (0 mm)
Case Length 11 (11 mm)
Total Length 10 (1.0 m)
Connector Type 02 (Miniature coaxial ClickLoc)
Agency Approval 05 (CSA, ATEX, IECEx)

Hardware Specifications

Parameter Specification
Model 330103-00-11-10-02-05
Brand Bently Nevada
Origin USA
Weight Not specified
Dimensions 11 mm (Case Length)
Operating Temp -52 deg C to +177 deg C
Power Consumption Passive (Powered via Proximitor)
Linear Range 0.25 mm to 2.3 mm

Eddy-Current Probe Scaling and Rotor Dynamics

The 330103-00-11-10-02-05 transducer utilizes the eddy-current principle for non-contact displacement monitoring, requiring a calibrated scaling factor of 7.87 V/mm. During commissioning, gap voltage validation is mandatory; the recommended setting of -9 VDC (approximately 1.27 mm) ensures the probe operates within the linear portion of its output curve. Accurate gap positioning is necessary for the observation of rotor dynamics, including shaft centerline behavior and radial vibration amplitude. To ensure signal integrity and enable effective cross-talk suppression, physical separation between adjacent proximity sensors must be maintained according to standard machinery monitoring configurations.

Frequently Asked Questions

Q: Can the 1.0 m system length be modified in the field?

A: No. The system is factory-calibrated as a matched assembly consisting of the probe, integral cable, and Proximitor sensor. Field-modifying the cable length alters the electrical impedance and resonant frequency, which will introduce significant measurement inaccuracies.

Q: Are these probes pressure-tested for high-pressure fluid environments?

A: The probe includes a Viton O-ring seal to manage differential pressure between the tip and case. However, standard units are not pressure-tested before shipment. Contact the manufacturer if the application requires certified high-pressure sealing.

Field Installation Guidelines

  • Mounting: Secure the probe in a rigid, non-conductive bracket. Verify that the probe tip is perpendicular to the shaft surface to prevent measurement skew.
  • Grounding: The probe housing is conductive; ensure the mounting bracket is bonded to the machine ground to maintain electromagnetic compatibility (EMC).
  • Connector Integrity: Use the ClickLoc connector mechanism for all coupling points. Clean the mating faces with an approved electrical contact cleaner prior to assembly to prevent signal attenuation.
  • Cable Routing: Route the coaxial cable through dedicated metallic conduit, maintaining physical separation from high-voltage AC lines to prevent induced noise on the output signal.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.

You may also like