  • Manufacturer: Allen Bradley

  • Product No.: 1734-IB8S

  • Product Type: Safety Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 820g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Configured for safety-rated signal acquisition in POINT I/O networks, the Allen Bradley 1734-IB8S (1734-IB8S) Safety Module provides direct physical/electrical execution of safety-critical input and output monitoring within industrial control platforms.

Hardware Specifications

Parameter Specification
Model 1734-IB8S
Brand Allen Bradley
Origin USA
Weight 0.09 kg
Dimensions Not Specified
Operating Temp -20 to 55 deg C
Power Consumption 1.4 W
Input Channels 8 (Current Sinking)
Output Channels 4 (Current Sourcing)
Reaction Time < 16.2 ms

Safety Integrity and Fail-Safe State Execution

The 1734-IB8S is designed to meet strict SIL3 certification requirements, ensuring robust performance in safety-instrumented systems. The module utilizes a safety-rated architecture to execute fail-safe state transitions upon detection of internal hardware diagnostics or loss of communication with the safety controller. Its design incorporates galvanic isolation between field inputs and backplane circuitry to prevent common-mode electrical faults. The safety-rated outputs are capable of sourcing current while maintaining diagnostic coverage, allowing the safety controller to verify the integrity of the connected final control elements and ensure immediate transition to a safe state when required.

Frequently Asked Questions

Q: Can this module be hot-swapped while the safety network is energized?

A: No. Due to the safety-critical nature of the hardware, hot-swapping is not permitted. The safety system must be de-energized to prevent unintended safety trips or faults resulting from transient electrical noise during module insertion or removal.

Q: How is the off-state voltage threshold verified for safety compliance?

A: The input circuitry is rated to recognize a maximum off-state voltage of 5 VDC and a current of 1.3 mA. Field signals exceeding these thresholds will be registered as an on-state, which must be accounted for during the selection of field sensors to prevent unsafe operation.

Field Installation Guidelines

  1. Mount the module on a standard 35 mm DIN-rail, ensuring proper alignment with the mounting base to maintain mechanical stability and electrical contact.
  2. Terminate all safety-rated field wiring according to the provided wiring diagram, ensuring correct polarity for sinking inputs and sourcing outputs.
  3. Use only shielded, low-capacitance cable for safety inputs to minimize signal corruption and to meet Electromagnetic Compatibility (EMC) requirements.
  4. Verify that the cable shields are grounded at the point of origin or the system cabinet as specified in the safety manual to prevent ground loops.
  5. Ensure the input current remains above the 3.3 mA minimum on-state threshold to maintain a valid signal status in the safety controller logic.
  6. Upon initial power-up, perform a full safety system validation test to verify that all inputs and outputs correspond correctly to the programmed logic and that no fault bits are present.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.