Allen Bradley
Allen-Bradley 1771-NOC N-Series Analog I/O Module
Manufacturer: Allen Bradley
Product No.: 1771-NOC
Product Type: Analog I/O Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1220g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Allen-Bradley 1771-NOC is an N-Series 8-channel isolated analog current output module for PLC-5 systems. It provides high-resolution 0–25 mA current sourcing outputs with 14-bit resolution (3.20 µA/bit), making it ideal for precise control of pneumatic positioners, valve actuators, and legacy 4–20 mA instrumentation loops in process control applications.
Key Specifications
- Module Type: N-Series Analog Output
- Number of Outputs: 8 isolated current outputs
- Output Type: Current sourcing
- Output Range: 0–25 mA
- Resolution: 3.20 µA/bit (approximately 14-bit)
- Output Impedance: >1 MΩ
- Backplane Current: 2.9 A (at 20 mA/output); 3.3 A (at 25 mA/output)
- Power Dissipation: 5.5 W at 5 VDC
- Data Format: BCD or natural binary
- Update Time: 25 ms maximum
- Offset Drift: ±1 µA/°C
- Gain Drift: ±50 ppm/°C
- Output Overvoltage Protection: 140 VAC RMS continuous
- RTP Compatibility: 1771-RTP3 (fused) / 1771-RTP4 (unfused)
- Wiring Arm: 1771-WH
- Operating Temperature: 0–60 °C
- Storage Temperature: −40–85 °C
- Humidity: 5–95% non-condensing
Features & Benefits
- Extended 0–25 mA Range: Supports standard 4–20 mA loops plus extended range for specific pneumatic positioners and legacy devices
- High 14-Bit Resolution: 3.20 µA/bit enables smooth, step-free control signals minimizing valve hunting
- Isolated Outputs: Channel-to-channel isolation reduces ground loops and improves measurement integrity
- Programmable Reset Values: Each channel configurable for safe shutdown conditions
- Flexible RTP Options: Compatible with fused (1771-RTP3) or unfused (1771-RTP4) remote terminal blocks
- Robust Protection: 140 VAC RMS continuous overvoltage protection safeguards output circuitry
Applications
- Pneumatic valve positioner control
- Analog loop current instrumentation
- Proportional control in process industries
- Variable speed drive analog references
- Damper and actuator positioning
Installation Guide
- Chassis Power Verification: Ensure the 1771 chassis power supply can deliver 3.3A at 5VDC for full-load operation. This is a high-current module.
- RTP Selection: Choose 1771-RTP3 (fused) for applications requiring individual channel fuse protection, or 1771-RTP4 (unfused) for simplified wiring.
- Module Installation: Insert the 1771-NOC into the 1771 chassis slot. Attach the 1771-WH wiring arm for field connections.
- Field Wiring: Connect current loop devices to the RTP terminals. Verify loop impedance is compatible with the >1 MΩ output impedance specification.
- Configuration: Set data format (BCD or natural binary) and programmable reset values per application requirements via PLC-5 programming software.
- Calibration Check: Verify output accuracy across the 0–25 mA range using a calibrated current meter before commissioning.
FAQ
Q: Can the 1771-NOC output voltage signals?
A: No. The 1771-NOC is strictly a current sourcing module (0–25 mA). For voltage output (e.g., 0–10V), select a different 1771-N series module rated for voltage output.
Q: Why does this module draw so much backplane current?
A: The 1771-NOC sources current directly from the backplane to drive field loads. At full 25 mA per channel, it draws up to 3.3A. Ensure your power supply is adequately sized.
Q: What is the difference between 1771-RTP3 and 1771-RTP4?
A: 1771-RTP3 includes individual channel fuses for protection; 1771-RTP4 is unfused for applications where external protection is provided.
Q: Is the 0–25 mA range compatible with standard 4–20 mA devices?
A: Yes. The 0–25 mA range fully encompasses the 4–20 mA standard. Program your output scaling accordingly in the PLC-5 processor.
Selection Tips
- Critical: Verify chassis power supply capacity (3.3A at 5VDC max) before installing this module
- Confirm field devices accept 0–25 mA current signals; some devices are limited to 4–20 mA
- Select fused RTP (1771-RTP3) for safety-critical applications
- Consider loop impedance and cable length to ensure signal integrity
- For new installations, evaluate ControlLogix 1756-OF8I or CompactLogix analog output modules
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag