Skip to product information
Bently Nevada 136180-01

Bently Nevada

Bently Nevada 3500/92 136180-01 Communication Gateway Module

6 left
  • Manufacturer: Bently Nevada

  • Product No.: 136180-01

  • Product Type: Communication Gateway Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Description

The Bently Nevada 3500/92 136180-01 Communication Gateway Module serves as a critical interface for the 3500 Machinery Protection and Condition Monitoring System. It facilitates the exchange of rack-monitored values, alarm statuses, and diagnostic data between the 3500 monitoring rack and external supervisory systems, including DCS, PLC, and SCADA platforms. This module provides robust connectivity via Ethernet TCP/IP and serial interfaces, ensuring seamless integration into plant-wide automation architectures.

Features

  • Supports Ethernet TCP/IP (10BASE-T) and serial (RS-232, RS-422, RS-485) communication protocols.
  • Includes a Configurable Modbus Register Utility for flexible data mapping.
  • Compatible with Bently Nevada 3500 Rack Configuration and Data Acquisition software.
  • Standard RJ45 Ethernet connection for 10 Mbps star configuration networks.
  • Designed for integration with process control and asset management systems.

Applications

  • Power Generation: Monitoring of turbines, generators, and boiler feed pumps.
  • Oil & Gas / Petrochemical: Tracking of pumps, mixers, and reactors for process safety.
  • Water & Wastewater: Supervision of pumps and blowers for distribution reliability.
  • Process Industries: Steel production, mining, and pulp/paper operations.
  • Manufacturing: Monitoring of motors, gearboxes, and fans to optimize maintenance.

Technical Specifications

Model 3500/92 136180-01
Manufacturer Bently Nevada
Communication Link Ethernet (10Mbps, IEEE 802.3)
Protocols Modbus/TCP, Modbus RTU, Proprietary BNC
Operating Temperature -30 degC to +65 degC
Storage Temperature -40 degC to +85 degC
Humidity 95% non-condensing
Weight 0.8 kg

Installation Guidelines

  • ESD Protection: Always use a grounded wrist strap when handling the module to prevent electrostatic discharge damage.
  • Slot Requirements: The main module occupies one full-height front slot in the 3500 rack; the corresponding I/O module requires the rear slot directly behind it.
  • Firmware: Ensure firmware compatibility when integrating with existing I/O modules; upgrades may require replacing firmware ICs on the PWA.
  • Environment: Ensure adequate ventilation within the rack to maintain operating temperatures within the specified range.

FAQs

What is the primary function of the 3500/92?

The 3500/92 acts as a communication gateway, exporting rack-monitored data and alarm statuses to external control and automation systems.

Which communication protocols are supported?

The module supports Modbus RTU (serial), Modbus/TCP (Ethernet), and the proprietary Bently Nevada protocol used for configuration and data acquisition software.

Can this module communicate via serial?

Yes, the module supports serial communication via RS-232, RS-422, and RS-485 interfaces, typically implemented through an associated I/O module.

Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.