Emerson
Emerson DeltaV KJ4006X1-BT1 Analog Output Terminal Block 8-Channel
Manufacturer: Emerson
Product No.: KJ4006X1-BT1
Product Type: Terminal Block
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Overview
The Emerson KJ4006X1-BT1 is a Redundant Analog Output (AO) 8-Channel Terminal Block for DeltaV™ S-Series distributed control systems. It provides secure wiring termination for analog output channels, with per-channel fused protection and redundancy support for critical control loops.
Technical Specifications
- Manufacturer: Emerson
- Model: KJ4006X1-BT1
- Type: Redundant AO 8-Channel Terminal Block
- Signal Support: Analog output (typically 4–20 mA)
- Field Power: 30 VDC @ 200 mA
- Weight: ~0.26 – 1.36 kg (varies by source)
Environmental & Safety Ratings
- Operating Temperature: −40 °C to +70 °C
- Shock: 10 g, ½ sine wave for 11 ms
- Vibration: 1 mm p-p (2–13.2 Hz); 0.7 g (13.2–150 Hz)
- Relative Humidity: 5 % – 95 % non-condensing
- Airborne Contaminants: ISA-S71.04-1985 Class G3
- Hazardous Area: ATEX II 3G Ex ec nC IIC Gc; IECEx; FM; UKEX; CSA; UL
Key Features
- 8-channel redundancy ensures backup for critical analog control loops
- Each channel includes fused protection for enhanced safety
- Rotary keying prevents mismatched I/O card installation
- Hot-swappable under safe wiring conditions (no field power, no I/O card installed)
FAQ
Q: What type of signals does this terminal block support?
A: It is designed for analog output signals, typically 4–20 mA loops driving control valves or VFDs.
Q: Can I replace this block without shutting down the DeltaV system?
A: Yes, but only when no I/O card is installed and no field wiring is connected. Otherwise, de-energize field power first.
Q: What key position is required?
A: Set the terminal block key position according to the specific AO I/O card installed.
Installation Guidelines
- Remove field power before connecting or disconnecting the terminal block.
- Set the rotary key to match the AO I/O card.
- Connect analog output wiring (4–20 mA) to the designated terminals.
- Verify fuse integrity per channel before energizing field power.
Selection Tips
- Select KJ4006X1-BT1 for redundant analog output termination in S-Series systems.
- Confirm your AO card calls for the BT1 terminal block key position.
- For non-redundant applications, a simplex terminal block may be sufficient.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag