Skip to product information
GE Fanuc IC694MDL241 Discrete Input Modules PACSystems RX3i

GE Fanuc

GE Fanuc IC694MDL241 Discrete Input Modules PACSystems RX3i

In stock
  • Manufacturer: GE Fanuc

  • Product No.: IC694MDL241

  • Product Type: Discrete Input Modules

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 110g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The GE Fanuc IC694MDL241, also cataloged as the IC694MDL241 Discrete Input Module, operates as a dedicated hardware component for sensing binary state changes within PACSystems RX3i platforms. The unit processes digital signals from field apparatus such as pushbuttons, limit switches, and electronic proximity sensors, translating electrical potentials into logical inputs for execution by the central processing unit.

Hardware Specifications

Parameter Specification
Model IC694MDL241
Brand GE Fanuc (Emerson Automation)
Origin United States
Weight 0.26 kg (0.56 lbs)
Dimensions 130 x 140 x 35 mm
Operating Temp 0 to 60 deg C
Power Consumption 80 mA at +5 VDC (backplane bus), 125 mA at +24 VDC (isolated supply)
Number of Inputs 16 discrete points (one isolated group with a single common)
Rated Input Voltage 24 VAC or 24 VDC
Input Voltage Range 0 to +30 VDC or 0 to +30 VAC
AC Frequency Range 50/60 Hz
Logic Type Positive or Negative Logic (sink/source for DC circuits)
Input Current 7 mA typical at rated voltage
On-state Voltage 11.5 VAC or VDC minimum
Off-state Voltage 0 to +4 VAC or VDC maximum
On-state Current 3.2 mA minimum
Off-state Current 1.0 mA maximum
On Response Time 12 ms typical
Off Response Time 28 ms typical
Isolation 250 VAC continuous (field-to-backplane / optical and frame ground)

Industrial Control & Deterministic Backplane Communication

The module interfaces directly with the controller backplane to maintain rigid transmission parameters across the universal chassis architecture. This structure ensures high-velocity bus communication velocity capabilities for data correlation with the main processor memory registers. Configured purely through engineering software, the interface scales seamlessly without physical jumper hardware, verifying immediate hardware registration and firmware flash compatibility across standard infrastructure layouts including Profinet and EtherNet/IP deterministic networks.

Frequently Asked Questions

Q: Can the IC694MDL241 module accept a mix of AC and DC field circuits simultaneously?

A: No, because all 16 input points share a single internal common line terminal, the entire module must be designated exclusively for either AC inputs or DC inputs within a given installation block.

Q: How can an internal circuit failure or state change be physically verified on the module faceplate?

A: The module contains 16 faceplate-mounted green Light Emitting Diodes (LEDs) arranged linearly, which track and indicate the real-time ON or OFF state of each specific field input channel.

Q: Is this module capable of being extracted or replaced while the RX3i chassis is powered?

A: Yes, the module structural layout supports hot-swap operations under backplane power, permitting direct module substitution when execution logic and structural conditions allow system maintenance routines.

Field Installation Guidelines

  • Chassis Engagement: Align and slide the module into the desired slot on the RX3i Universal Backplane (IC695CHSxxx) or Expansion Backplane (IC694CHSxxx). Ensure the upper and lower plastic retaining clips securely snap into place to lock the chassis bus contact points.
  • DC Logic Termination: For positive logic configurations (sink mode), connect the common terminal (pin 1) to the negative side of the 24 VDC field power supply. For negative logic configurations (source mode), connect the common terminal to the positive side of the 24 VDC power supply.
  • AC Device Integration: When deploying AC field inputs, connect the user-supplied AC neutral line to the common terminal block pin to establish a consistent path for the internal optical couplers.
  • Terminal Wiring Restrictions: Utilize standard high-density terminal blocks (IC694TBB032 or IC694TBS032). Maintain strict separation between low-voltage signal conduits and high-current power cables within the panel wiring trays to reduce electromagnetic interference.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.