GE Fanuc
GE | IS200VRTDH1D | Mark VI RTD Input Board
Manufacturer: GE Fanuc
Product No.: IS200VRTDH1D
Product Type: Mark VI RTD Input Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The GE IS200VRTDH1D (IS200VRTDH1D) functions as a dedicated Resistance Temperature Detector (RTD) input board within the Speedtronic Mark VI gas and steam turbine control framework. This 100% brand new, authentic factory-sealed component accepts direct temperature signals from field-mounted RTD sensors embedded deep within critical mechanical systems. Industrial operators deploy this board in thermal power stations, petrochemical facilities, and heavy manufacturing plants to monitor bearing temperatures, exhaust gas profiles, and generator stator windings. By translating raw resistance changes into precise, digitized temperature values, the board provides the core control system with real-time process visibility. This fast, deterministic feedback loop enables immediate thermal protection execution, prevents mechanical breakdown from overheating, and eliminates costly unplanned turbine shutdowns.
Part Number Breakdown
The alpha-numeric structure of the IS200VRTDH1D model number indicates the hardware assembly architecture developed by General Electric:
-
IS200: Designates the standard printed circuit board (PCB) assembly platform within the Mark VI system line.
-
VRTD: Establishes the functional acronym for the VME-based Resistance Temperature Detector input module.
-
H1: Specifies the group one configuration category, dictating the baseline channel density and component layout.
-
D: Indicates the latest functional hardware revision layer certified by the factory.
Technical Specifications
| Parameter | Specification Profile |
| Model | IS200VRTDH1D |
| Brand | General Electric (GE) |
| Series | Mark VI Speedtronic |
| Module Type | RTD Input Board |
| Origin | United States (USA) |
| Channel Capacity | 12 discrete RTD input channels |
| Supported RTD Types | 10 Ohm Copper, 100 Ohm Platinum, 120 Ohm Nickel, 200 Ohm Platinum |
| A/D Conversion | Dedicated 16-bit analog-to-digital converters per group |
| Scan Rate | 25 Hz nominal frame rate |
| Operating Temperature | 0-60 Celsius (32-140 deg F) |
| Storage Temperature | -40-85 Celsius |
| Relative Humidity | 5-95 percent non-condensing |
| Physical Dimensions | Standard VME card dimensions |
Engineering Advantages
The IS200VRTDH1D provides robust structural and electrical solutions to solve common temperature logging challenges in harsh environments:
-
Advanced Noise Suppression and Isolation: High-frequency electrical noise from generator fields often corrupts low-voltage RTD signals. This board features onboard differential filtering networks and galvanic isolation barriers. These components eliminate common-mode noise and prevent ground-loop cross-talk, preserving measurement accuracy over extended field cable runs.
-
Open/Short Circuit Detection Loop: The internal diagnostics continuously check sensor line health. If a field wire breaks or shorts out, the board flags the precise channel instantly and logs a diagnostic alarm to the CPU. This prevents the control system from misinterpreting a broken wire as an over-temperature trip, avoiding false turbine shutdowns.
-
Dynamic Lead Wire Compensation: The board utilizes a three-wire configuration tracking architecture to calculate lead-wire resistance dynamically. It automatically subtracts cable resistance from the sensor reading, ensuring highly accurate temperature data even when the physical RTD sits hundreds of meters away from the control cabinet.
FAQs
-
Does this IS200VRTDH1D board arrive with original packaging and documentation?
Yes. We supply this component in 100% brand new, original factory-sealed condition, complete with original box protection and factory serial labels.
-
Can the IS200VRTDH1D replace an older revision like the H1A or H1B?
The "D" suffix indicates the latest factory update, which generally offers backwards compatibility with earlier revisions like the H1A, H1B, or H1C within the same group block. However, you should check your Mark VI system configuration files and toolbox software version to ensure seamless hardware registration.
-
What type of RTD sensors can I connect to this board?
The board natively supports standard industrial 3-wire RTDs, including 100 Ohm Platinum (Pt100), 10 Ohm Copper, 120 Ohm Nickel, and 200 Ohm Platinum sensors. You can configure each channel independently via the system software.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
What is an Interposing Relay in a PLC System?
What is an Interposing Relay in a PLC System?
Rockwell CompactLogix 5380 Controller: Advancing Smart Manufacturing with Precision and Connectivity
Rockwell CompactLogix 5380 Controller: Advancing Smart Manufacturing with Precision and Connectivity