GE Fanuc
GE Mark V DC Power Connect Board DS200PCCAG7ACB
Manufacturer: GE Fanuc
Product No.: DS200PCCAG7ACB
Product Type: Mark V DC Power Connect Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 620g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The DS200PCCAG7ACB (DS200PCCAG7ACB) functions as a central DC Power Connect Board within the General Electric Mark V Speedtronic control cabinet. This module acts as the primary junction for distributing 125 VDC and 24 VDC control power from the main distribution modules to the individual functional boards in the core racks. It conditions and filters power rails to ensure that sensitive logic processors receive stable, ripple-free electricity. This unit arrives as 100% Brand New and original, providing the high-integrity electrical paths necessary to prevent intermittent resets and communication errors in heavy-duty gas and steam turbine applications.
Technical Specifications
The DS200PCCAG7ACB utilizes high-current traces and specialized filtering components to manage the cabinet's internal DC grid.
| Parameter | Specification |
| Model | DS200PCCAG7ACB |
| Brand | General Electric (GE) |
| Series | Mark V Speedtronic |
| Module Type | DC Power Connect Board (PCCA) |
| Input Voltage | 125 VDC nominal / 24 VDC Control Power |
| Interface | Multiple 50-pin ribbon headers and high-density connectors |
| Protection | Integrated surge suppression and noise filtering |
| Operating Temp | 0 to 60 deg C |
| Weight | 1.05 kg |
| Dimensions | 28.0 cm x 15.2 cm |
Engineering Advantages
-
High-Integrity Power Routing: The PCCA board eliminates the need for complex point-to-point wiring by centralizing power distribution. This design simplifies the cabinet layout and reduces the potential for wiring faults during system upgrades.
-
Active Noise Suppression: Integrated filtering circuits mitigate electromagnetic interference (EMI) originating from the plant's DC bus. This protection ensures that high-frequency noise does not compromise the accuracy of sensitive analog-to-digital converters in the control loop.
-
Industrial-Grade Durability: GE engineered this board with heavy-weight copper traces to handle inrush currents without localized overheating. The use of high-temperature rated components allows the board to operate reliably in the non-ventilated enclosures common in turbine halls.
-
Gold-Plated Interconnects: The board features gold-plated connector pins to resist oxidation. This is critical in industrial environments where sulfur or high humidity often causes contact resistance and "Power Supply Fault" alarms in legacy systems.
Installation and Field Guidelines
-
Chassis Isolation: Verify that the mounting standoffs remain clear of any conductive debris. Ensure the board mounts securely to the rack to maintain a consistent ground reference for the filtering circuits.
-
Connector Alignment: When attaching the 50-pin ribbon cables, verify that the alignment notch matches the header orientation. Forceful insertion into misaligned headers can bend pins and cause catastrophic shorts across the DC power rails.
-
Surge Suppressor Inspection: Before installation, visually inspect the Metal Oxide Varistors (MOVs) on the board. While this unit is brand new, MOVs are the first line of defense; ensure they show no signs of transit damage to guarantee full surge protection upon startup.
FAQs
Q: What distinguishes the "G7ACB" revision from the "G6" series?
A: The "G7" indicates a specific grouping of power distribution channels and connector layouts. The "ACB" suffix denotes a later hardware revision that incorporates improved dielectric insulation and updated component tolerances for better long-term reliability. It replaces older G7 series boards as a direct drop-in.
Q: Can a fault on the DS200PCCAG7ACB cause a turbine trip?
A: Yes. Because this board routes power to the core processors (, , ), a failure in a trace or a shorted filtering capacitor can drop the control power, triggering an immediate fail-safe shutdown of the turbine.
Q: Does this board require software configuration in the HMI?
A: No. The PCCA board is a purely hardware-based power distribution component. It does not contain microprocessors or programmable logic, so it requires no software downloads to become operational.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.